Use and Care Manual

12. To prevent accidents, turn off the tool, detach the air supply, safely discharge any
residual air pressure in the tool, and release the throttle and/or turn the switch to its
off position after use. Clean external surfaces of the tool with clean, dry cloth, and
apply a thin coat of tool oil. Then store the tool indoors out of children's reach.
13. When tightening, if needed, check the recommended torque specification for the
nut and tighten the nut further, to the proper setting, using a torque wrench
(sold separately).
If the tool still does not have sufficient force at maximum pressure and sufficient airflow,
then a larger tool may be required.
CAUTION! TO PREVENT INJURY FROM TOOL OR ACCESSORY FAILURE:
Do not exceed the tool's maximum air pressure rating.
1-800-348-5004
customerservice@focus-ontools.com
7
1. If an automatic oiler is not used, add a few drops of Pneumatic Tool Oil to the airline
connection before use. Add a few drops more after each hour of continual use.
2. Select the desired size 3/8" drive impact socket (sold separately).
3. Push the socket onto the Anvil until it clicks into place.
4. Connect the air hose and turn on the air compressor.
5. Adjust the Air Regulator on the Impact Wrench as needed.
• Turn toward the “H” arrow to increase power.
• Turn toward the “L” arrow to decrease power.
6. Press the Reverse Lever to set the direction:
• Reverse - counterclockwise rotation Press to left of handle.
• Forward - clockwise rotation Press to right of handle.
7. If tightening the nut, tighten by hand as much as possible.
8. Position the socket on the Impact Wrench over the nut.
9. Grip the Impact Wrench firmly with two hands and gently squeeze the Trigger.
10. When the nut is tightened or loosened, release the Trigger.
11. If the tool requires more force to accomplish the task, verify that the tool receives
sufficient, unobstructed airflow (CFM) and increase the pressure (PSI) output of the
regulator up to the maximum air pressure rating of this tool.
Note: Turn off the air compressor and disconnect the air hose when changing sockets.
GENERAL OPERATING INSTRUCTIONS