TRANSPORTING/STORAGE
When transportingthe generator, turn the engine switch and the fuel valve
OFF. Keep the generatorlevel to preventfuel spillage, Fuel vapor or spilled
fuel may ignite.
Contact with a hot engine or exhaust system can cause
serious burns or fires. Let the engine cool before transporting or
storing the generator.
Take care not to drop orstrike the generator whentransporting. Do not place
heavy objects on the generator,
Before storing the unit for an extended period:
1. Be sure the storage area is free of excessive humidity and dust.
2. Service according to the table below:
STORAGE TIME RECOMMENDED SERVICE PROCEDURE TO
PREVENT HARD STARTING
Lessthan 1 month No preparationrequired
Fill with fresh gasoline and add gasoline
1 to 2 months conditioner*.
Fill with fresh gasoline and add gasoline
conditioner*.
2 months to I year Drain the carburetor float bowl
Drain the rue! sediment cup
Fill with fresh gasoline and add gasoline
conditioner*,
DraWnthe carburetor float bowl
1 year or more Drain the fuel sediment cup
Remove the spark plug. Put atablespoon of engine
oil into thecylinder. Turn the engineslowly w{ththe
pull rope to distribute the oil. Reinstall the spark
plug.
Change the engine oil
A_r removal from storage,drain the stored gasoline
into a suitable container, and fill w thfresh gasoline
before starting.
30