Remote controlling Cubase
The Remote Control Editor
4. Click on another control to set the Learn focus to that control and assign a
parameter to it.
5. Press [Esc] to end Learn mode.
Removing the Parameter assignment
To remove the parameter assignment for a cell, activate Learn mode, select the
cell, and press [Del] or [Backspace].
To remove all assignments, click the “Remove All Assignments” button.
Assignment Status
You can show the current assignment of all cells in a layout by activating the “i” button
in the top right corner of the editor. This is useful to get a quick overview of the
parameters that are assigned to the available controls.
Editing the Layout
In the Layout section, you can perform a number of editing operations and arrange the
pages to your liking.
Making Name Settings for the Cells
The top three text fields in the Inspector can be used to specify the names for a cell.
This is useful if you are working with hardware devices that have value fields that only
display a limited number of characters, for example. The first text field shows the long
name, as it is shown in the cell. In the second field, you can enter a name that can
contain up to 8 characters, and up to 4 characters in the third.
Rearranging the order of a page or a cell
To copy the settings of one cell to another, select a cell, press [Alt]/[Option] and
drag it to another cell.
To move a cell, drag it to an empty cell.
To swap the contents of two cells, press [Ctrl]/[Command] and drag one cell to
the other.