User Manual
Software
UR816C Operation Manual 7
2 Mode
Lets you select the latency mode.
Settings: Low Latency, Standard, Stable
3 Buffer Size
Lets you select the buffer size for the ASIO driver. The
range varies depending on the specified sample rate. The
lower the value of the ASIO buffer size, the lower the value
of audio latency.
4 Input Latency/Output Latency
Indicates the latency (delay time) for the audio input and
output in millisecond units.
About Window
Indicates the version and copyright information of the
audio driver.
Sample Rate Descriptions
Low Latency Low latency mode. High-performance
computer is required.
Standard Standard latency mode.
Stable High latency mode. This prioritizes
stability for low-performance computer
and high-load projects.
Sample Rate Range
44.1 kHz / 48 kHz 32 Samples – 2048 Samples
88.2 kHz / 96 kHz 64 Samples – 4096 Samples
176.4 kHz / 192 kHz 128 Samples – 8192 Samples
How to select the sample rate and the clock
source (Mac)
You can select the sample rate in the [Audio MIDI
Setup] window. Select the sample rate from the
[Applications] [Utilities] [Audio MIDI Setup]
[Format] menu. Select the clock source in the [Clock
source].
How to select the buffer size (Mac)
You can select the buffer size in the settings window for
each application (DAW software, etc.).
From the Cubase series menu, select [Studio]
[Studio Setup], then click [Control Panel] in [Steinberg
UR816C] or [Steinberg UR816C (High Precision)] in the
menu on the left side of the window.
The method for opening the settings window is different
for each application.
Using with 32-bit Integer processing (Mac)
[Steinberg UR816C] or [Steinberg UR816C (High
Precision)] is shown in the [ASIO Driver] setting on the
Cubase series program. Select [Steinberg UR816C
(High Precision)] when processing at 32-bit integer
resolutions between Cubase and the driver.