User manual

- 10 -
The SensorLight can be put into service after mount-
ing the sensor unit and connecting the light to the
mains power supply.
Functions ,
Twilight setting
(response threshold)
(factory setting:
daylight operation 2000 lux)
The sensor's response threshold can be infinitely var-
ied from 2–2000 lux.
Control dial set to 1 = daylight operation approx.
2000 lux.
Control dial set to 6 = twilight operation approx. 2 lux.
To adjust the detection zone in daylight, the control
dial must be set to number 1 (daylight operation).
Switch-off delay
(time setting)
(factory setting: 5 sec.)
Light ON duration can be infinitely varied from
5 sec. to 15 min.
Control dial set to 1 = shortest time (5 sec.)
Control dial set to 6 = longest time (15 min.)
It is recommended to select the shortest time
(setting 1) for adjusting the detection zone.
2 – 2000 lux
5 sec. – 15 min
Installation/wall mounting –,
The site of installation should be at least 50 cm away
from another light because heat radiated from it may
activate the system. To achieve the specified max.
reach of 12 m, the light should be installed at a height
of approx. 2 m.
Connecting the mains supply lead (see illustration)
The mains lead consists of a 2-3 phase cable.
L = phase conductor (usually black or brown)
N = neutral conductor (usually blue)
PE = protective earth conductor (green/yellow)
If you are in any doubt, you must identify the cables
using a voltage tester; now disconnect the power
supply again. Connect phase (L), neutral (N) and pro-
tective earth (PE) to the terminals.
Installation instructions
Congratulations on purchasing your new STEINEL
sensor light and thank you for the confidence you
have shown in us. You have chosen a high-quality
product that has been manufactured, tested and
packed with the greatest care.
GB
Safety warnings
n Disconnect the mains power supply before
attempting any work on the unit!
n During installation, the electrical wiring being
connected must be dead. Therefore, switch off
the power first and use a voltage tester to make
sure the wiring is off circuit.
Principle
The integrated infrared sensor is equipped with two
120° pyro sensors which detect the invisible heat
emitted by moving objects (people, animals etc.).
The heat detected is converted electronically into a
signal that switches the light on automatically. Heat is
not detected through obstacles, such as walls or
panes of glass. Heat radiation of this type will, there-
fore, not trigger the sensor. The two pyro sensors
- 9 -
Please familiarise yourself with these instructions
before attempting to install the sensor light because
prolonged reliable and trouble-free operation will only
be ensured if it is fitted properly.
We hope your new STEINEL sensor light will bring
you lasting pleasure.
n Installing the sensor light involves work on the
mains voltage supply. This work must therefore
be carried out professionally in accordance with
applicable national wiring regulations and electrical
operating conditions. (
D
-VDE 0100,
A
-ÖVE / ÖNORM E8001-1,
- SEV 1000)
have an angle of coverage of 240° with an angle of
aperture of 180°.
Important: The most reliable way of detecting motion
is to install the sensor light with the sensor aimed
across the direction in which a person would walk
and by ensuring that no obstacles (such as trees and
walls, for example) obstruct the line of sensor vision.
Note on Fig.
: For connection, the light arm must
be clamped in the retaining bracket so as not to exert
tension on the internal conductors.
Note on Fig.
: The lampholder turns, permitting
precision adjustment.
Note: A mains switch for switching the unit ON and
OFF may of course be installed in the power supply
lead. A mains switch is required for the manual over-
ride function (see Manual override function) .
Note: for technical reasons, the LED lamp may flicker
slightly to moderately at certain dimming levels. If this
occurs, alter the dimming level slightly.
Dear Customer
GB
Technical specifications
Dimensions (H x W x D): 426 x Ø 102 x 177 mm
Power supply: 230-240 V/50 Hz
Output: 100 watts max./E 27
Angle of coverage: 240° with 180° angle of aperture
Detection reach: 12 m max.
Twilight setting: 2 – 2000 lux
Time setting: 5 sec. – 15 min.
Manual override: selectable (4 hrs.)
Condition: switch in mains power supply lead
IP rating: IP 44
Protection class: II
Temperature range: - 20 °C to + 50 °C
Technical specifications for the enclosed LED lamp
Output: 8.6 W / E27
Luminous flux/efficiency: 700 lm / 81.4 lm/W
Colour-rendering index: RA ≥ 80
Colour temperature: 3000 K (warm white)
LED life expectancy: 25,000 hours