User manual

- 11 -
Operation and maintenance
The unit is not suitable for burglary alarm systems as
it is not tamperproof in the manner prescribed for
such systems. Weather can affect operation of the
sensor-switched LED floodlight. Strong gusts of wind,
snow, rain and hail may cause the light to come 'ON'
when it is not wanted because the sensor is unable to
distinguish sudden changes in temperature from
sources of heat.
The detector lens may be cleaned with a damp cloth
if it gets dirty (do not use cleaning agents).
Technical specifications
Installation –
The site of installation should be at least 50 cm
away from another light because heat radiated from
it may activate the system. To obtain the specified
max. reach of 14 m, the sensor should be installed
at a height of approx. 2 m. Install the unit on a firm
surface to avoid unintentional triggering.
The mains supply lead is a 3-core cable.
- 10 -
Functions
Light threshold
(response threshold)
(factory setting:
Daylight operation at 2000 lux)
Sensor response threshold can be infinitely varied
from 2 – 2000 lux.
Control dial set to = daylight operation
approx. 2000 lux.
Control dial set to = twilight operation approx. 2 lux.
To adjust the detection zone in daylight, the control
dial must be set to (daylight operation).
Switch-off delay
(time setting)
(factory setting: 8 sec.)
Control dial set to = shortest time (8 sec.)
Control dial set to + = longest time (35 min.)
When setting the detection zone, we recommend
selecting the shortest time.
Reach setting/adjustment
The detection zone setting can be optimised to
suit requirements. Reach 2 – 14 m.
a) By swivelling the sensor unit through 90°and tilting
it through 180°.
b) using adhesive shrouds, e.g. to mask out paths
or neighbouring property.
L = phase conductor (usually black or brown)
N = neutral conductor (usually blue)
PE = protective-earth conductor (green/yellow)
Important: Connecting the conductors to the wrong
terminals will produce a short circuit in the unit or
your fuse box at a later stage when you come to
switch the power on. In this case, you must identify
the individual cables and re-connect them. A suitable
mains switch for switching the light "ON" and "OFF"
can be installed in the mains lead.
2 – 2000 lux
8 sec. – 35 min.
XLed home 1 XLed home 3
Dimensions (H x W x D): 175 x 210 x 180 mm 206 x 234 x 180 mm
Output: 198 LEDs approx. 12 W 330 LEDs approx. 18 W
Light colour: approx. 6700 kelvin (cold white) approx. 6700 kelvin (cold white)
Luminous flux: 720 lumens 1426 lumens
Projected area: Front view: 294 cm
2
Front view: 376 cm
2
Side view: 160 cm
2
Side view: 169 cm
2
Weight: 1.1 kg 1.3 kg
XLed Home 1 / XLed Home 3
Detection angle: 140° with sneak-by guard
Additional switching capacity: 800 W max. (resistive load, e.g. filament bulbs)
400 W max. (uncorrected, inductive, cos ϕ = 0.5, e.g. fluorescent lamps)
400 W max. (electronic ballasts, capacitive, e.g. low-energy lamps,
4 each max., ≤ 88 F)
LED lifespan: 30 years (4.5 hrs./day)
Detection reach: 14 m max.
Sensor unit 180° swivelling, 90° tilting
adjustment range:
Floodlight 180° swivelling, 120° tilting
adjustment range:
Time setting: 8 sec. – 35 min.
Twilight setting: 2 – 2000 lux
IP rating: IP 44
Protection class: I
Temperature range: -20° C to +40° C
GB