Instructions

- 14 - - 15 -
GB
10. Technical specifications
Dimensions, Ø × H 78 × 89 mm
Minimum installation depth 54 mm less thickness of ceiling panel
Mains power supply 220-240 V, 50 / 60 Hz
Output Incandescent lamps, max. 1000 W
at 230 V AC
Fluorescent lamps, max. 500 VA
at cos j = 0.5, inductive load
at 230 V AC
LED lamps, max. 6×58 W,
C ≤ 132 F at 230 V AC
*1)
Sensor technology Passive infrared
Angle of coverage 360°
Reach max. 4 m
Time setting 8 s - 35 min
Twilight setting 2-2000 lux
IP rating IP54
Temperature range -20°C to +40°C
*1)
Fluorescent lamps, low-energy lamps, LED lights with electronic ballast
(total capacity of all ballasts connected below the level stated).
Service:
Our Customer Service Department
will repair faults not covered by
warranty or after the warranty period
has expired. Please send the product
well-packed to your nearest
Service Centre.
maintenance. Further consequen-
tial damage to other objects shall be
excluded. Claims under the warran-
ty will only be accepted if the unit is
sent fully assembled and well-packed
with a brief description of the fault, a
receipt or invoice (date of purchase
and dealer's stamp) to the appropri-
ate Service Centre.
11. Troubleshooting
Malfunction Cause Remedy
Without power
n Fuse faulty,
not switched ON
n Short circuit
n Replace fuse, turn ON
mains switch, check
lead with voltage tester
n Check connections
Does not switch ON
n Twilight setting in
night-time mode during
daytime operation
n Bulb faulty
n Mains power switch
OFF
n Fuse faulty
n Adjust setting
n Replace light bulbs
n Switch ON
n Fit new fuse, check
connection if necessary
Does not switch OFF
n Continuous movement
in the detection zone
n Light being operated
is located in detection
zone and keeps swit-
ching ON as a result of
temperature change
n Set to continuous ope-
ration via indoor two-
circuit single interruption
switch
n Check zone
n Check zone
n Set two-circuit single
interruption switch to
automatic operation
Keeps switching ON/OFF
n Light being operated
is located in detection
zone
n Animals moving in the
detection zone
n Check zone
n Check zone
Switches ON when it
should not
n Wind is moving trees
and bushes in the
detection zone
n Cars in the street are
being detected
n Sudden temperature
changes due to weather
(wind, rain, snow) or air
expelled from fans, open
windows
n Check zone
n Check zone
n Change detection
zone, change mounting
location