Instructions

- 30 - - 31 -- 30 -
10. Technical specifications
IR180UPeasy IR180APeasy
Dimensions (H×W×D) 81×81×57mm 82×72×67mm
Power supply 220-240V, 50/60Hz
Power consumption 25mW
Output
Incandescent / halogen lamp load
Fluorescent lamps, electronic ballast
Fluorescent lamps, uncorrected
Fluorescent lamps, series-corrected
Low-voltage halogen lamps
LED < 2 W
2 W < LED < 8 W
LED > 8 W
Capacitive load
200W
150W
150VA
150VA
200VA
40W
100W
160W
132µF
Minimum connected load with N: 1W
without N: 4W
Mounting height 1.1m
Sensor system Passive infrared
Angle of coverage 180° with 90° angle of aperture
Reach Max. 8 m tangential
Twilight setting 2-1000lux
Time setting 5 s - 30min
Temperature 0°C to +40°C
IP rating IP20 IP54
11. Troubleshooting
Malfunction Cause Remedy
Sensor switchWithout
voltage
Fuse has tripped, not
switched ON
Short circuit
Activate, change fuse,
turn ON mains switch,
checkWiringWith
voltage tester
Check connections
Sensor switch not
switching ON
Lamp faulty replace lamp
Sensor switch not
switching ON
Twilight setting in night-
time mode during
daytime operation
Fuse has tripped
Reset
Activate, change fuse,
check connection if
necessary
Sensor switch not
switching OFF
Continued
movementWithin the
detection zone
Light is in detection zone
and keeps switching ON
as a result of
temperature change
Other sensor switch is
connected in parallel and
still active
Check detection zone
Check detection zone
Wait for time setting of
the other sensor switch
to elapse
Sensor switch always
switches ON/OFF
Light being operated in
the detection zone
Animals moving in
detection zone
Check detection zone
Check detection zone
LEDs glowing, flickering LEDs responding too
sensitively
Connect neutral
conductor (N), change
lamp