Instructions

- 12 - - 13 -
GB
Operation/Function
Startup
L Plug the tool in.
L Switch the tool ON by pressing the ON/OFF but-
ton for two seconds. The tool immediately heats
up to the selected temperature.
L While it is heating up, the LED flashes red /
the display lights up blue.
L Once the LED shows red / the display lights up
green, the temperature setting range has been
reached and the hot-melt glue applicator is ready
for use.
L If the temperature range is too high, the LED /
display lights up red.
L Insert the hot-melt glue stick into the opening at
the rear of the tool.
L Switch the tool OFF by briefly pressing the ON/
OFF button.
Temperature setting
GluePRO400 LCD
L The temperature can be selected to an accuracy
of one degree from 40 to 230 degrees Celsius. On
leaving the factory, the tool is set to 190 degrees
Celsius.
L Press the SET button
6
. Keeping the SET button
pressed, select the chosen temperature via the
7
+
8
UP and DOWN buttons. The tempera-
ture you select is shown on the display.
L Releasing the
6
SET button shows you the tem-
perature now reached in the heating chamber.
L Keep the SET button pressed. Pressing the UP or
DOWN button automatically increases or reduces
temperature in steps of 1 degree. Keeping the UP
or DOWN button pressed for at least 3 seconds in-
creases or reduces temperature by 5 degrees.
L
Do not select any temperature higher than is
needed for applying the hot-melt adhesive!
Stroke adjustment
L Glue feed can be adjusted to suit any particular
application, giving you precision in selecting an ex-
act quantity of glue per stroke and letting you set
the feed trigger
12
for ease of use.
L The slide control for adjusting glue feed
3
adjusts
the trigger
12
to reduce or increase the quantity of
glue delivered.
L Pull the trigger and move the glue feed slide con-
trol
3
towards the nozzle until the tool delivers
the chosen quantity of glue per trigger pull or gives
you the delivery rate you find easy to work with.
L Adjust the slide control in the opposite direction to
restore the initial position.
Changing nozzles
Customised nozzles are available for specific applica-
tions. To change the nozzle, the tool must be warm
and unplugged. For this, heat up the GluePRO300
for no more than 45 seconds.
Heat the GluePRO400 LCD to no more than 100
degrees Celsius.
Switch the tool OFF once it has reached temperature.
1. Hold the tool with heat-protective gloves.
2. Unscrew nozzle
13
.
At this point, never pull the trigger!
3. Screw the replacement nozzle on hand-tight.
Other functions of GluePRO400LCD
LOC function
To avoid altering the chosen settings unintentionally,
the GluePRO400LCD comes with the Lockable
Override Control function (LOC). To find out how to
set the LOC function, contact our Service Department
on 05245 448 188.
Idle mode
After any selectable period, idle mode automatically
reduces the temperature in the heating element to a
temperature you can select. This depends on when
the button was last pressed. Idle state is indicated by
the blue flashing LED / blue flashing display. On leav-
ing the factory, this function is deactivated. To find
out how to set idle mode, contact our Service Depart-
ment on 05245 448 188.
Other functions of GluePRO400LCD
Explanations of the technical specifications on page 3
Nozzles
1. Long nozzle, 3 mm
Prod. No. 052737
2. Long nozzle, angled, 3 mm
Prod. No. 052744
3. Long nozzle, fine, 1.5 mm
Prod. No. 052928
4. Long nozzle, large, 4.5 mm
Prod. No. 052935
Glue sticks
1. General-purpose glue sticks, 300 mm, 600 g
Prod. No. 050092
2. Acrylate glue sticks, 300 mm, 600 g
Prod. No. 052416
3. Fast glue sticks, 300 mm, 600 g
Prod. No. 052430
4. Flex glue sticks, 300 mm, 600 g
Prod. No. 052423
5. Low Melt glue sticks, 300 mm, 600 g
Prod. No. 052409
Note:
Refer to data sheet with information on applying the
hot-melt adhesive. Data sheets and further information
are available at www.steinel-professional.de.
Your retailer keeps a stock of accessory nozzles.
Accessories
Display
Heating
element
Cause Remedy
"- - -" LOC function activated Deactivate LOC function.
(See "Other functions of GluePRO 400 LCD")
"Err" Warm Maximum temperature
exceeded
Let tool cool down.
Switch tool OFF and ON.
"Err" Cold Sensor short circuit
or sensor break
Replace heating chamber.
Please contact your service partner.
The LED on the GluePRO300 flashes rapidly to indi-
cate that a fault has occurred.
If the fault is indicated for more than 5 minutes,
please contact your service partner.
GluePRO400 LCD status indicators and error messages
GluePRO300 fault indication
L × W × H Dimensions Pmax Maximum output in watts
U Rated voltage in volts P
Ø** Rated input power in watts
T Temperature in °Celsius t
190 Heat-up time in minutes
m/t* Delivery rate per hour in kg m Weight without power cord in grams
* Depending on temperature and glue viscosity ** For 30 s of gluing / 60 s pause