User manual

1918
After the motion detector has been con-
nected and fastened to its wall mount,
the system can be switched ON.
Two setting options are available after
removing the decorative ring 2.
Switch-off delay (time setting)
(Factory setting: 10 sec.)
Light ON duration can infinitely varied from
approx. 10 sec. to a maximum of 15 min.
Control dial set to (1) =
shortest time (10 sec.)
Control dial set to (6) =
longest time (15 min.)
The shortest time setting is recommended
when adjusting the detection zone and per-
forming the function test.
Function
2 - 2000 lux
approx. 10 sec - max. 15 min
19
Technical specifications
Assuming an installation height of
2 m, the maximum reach of the sensor
is 12 m. Optimum adjustment of the
detection zone is possible according
to needs. The shrouds 6 provided
serve to cover any desired number of
lens segments and individually reduce
the reach. Fine adjustment is also
possible by turning the sensor hous-
ing 3 by ± 80°. The shrouds 6 can be
divided vertically or horizontally along
the grooved divisions, or cut with scis-
sors. After removing the decorative
ring 2, the shrouds are to be sus-
pended on the upper part of the sen-
sor lens. The decorative ring 2 is
subsequently to be reapplied and the
shrouds 6 are fixed firmly in place.
False switching by cars and pedestri-
ans, etc. is therefore ruled out, or risk
areas deliberately monitored.
Reach setting/adjustment
Dimensions (H x W x D): 90 x 60 x 100 mm
Output:
Filament bulbs,
1000 W max., operating on 230 V AC
Fluorescent lamp, 500 W max.,
at cos ϕ = 0.5, inductive load at 230 V AC
6 x 58 W each max., C ≤ 132 µF
operating on 230 V AC
*1)
Connection: 230–240 V, 50 Hz
Angle of coverage: 240° (with 180° angle of aperture)
Pivoting range of
the sensor: Fine adjustment ± 80°
Reach: max. 12 m (electronically stabilised)
Time setting: 10 sec. – 15 min.
Twilight setting: 2 – 2000 lux
IP rating: IP 54
*1)
Fluorescent lamps, low-energy bulbs, LED lights with electronic ballast
(total capacity of all connected ballasts below the value specified).
Twilight setting
(Factory setting: 2000 lux)
The sensor's response threshold can be
infinitely varied from 2 – 2000 lux.
Control dial set to (1) =
daylight operation at approx. 2000 lux.
Control dial set to (6) =
night-time operation at approx. 2 lux.
The adjusting screw must be turned fully
anti-clockwise when adjusting the detection
zone and performing the function test in
daylight.