User manual

1716
Troubleshooting
Sensor without power
Fuse faulty, not
switched "ON",
break in wiring
Short circuit
Fit new fuse; switch
"ON" mains switch;
check wiring with
voltage tester
Check connections
Sensor will not switch
"ON"
Twilight control set
to night-time mode
during daytime
operation
Bulb faulty
Mains switch "OFF"
Fuse faulty
Detection zone not
properly targeted
Internal electri-
cal fuse has been
activated (red LED
flashing rapidly)
Re-adjust
(control h)
Change bulb
Switch "ON"
Renew fuse,
check connection
if necessary
Re-adjust
Switch sensor
"OFF" and "ON"
again after approx.
5 sec.
Malfunction Cause Remedy
Sensor will not
switch "OFF"
Continued move-
ment in detection
zone
Sensor unit is not
properly engaged
Check detection
zone and re-adjust
if necessary
Lightly press sensor
unit to clip it into
place
Sensor doe not switch
"OFF" at around
midnight
External light
source (e.g. another
motion detector or
light) inactivating
the sensor
Shade sensor from
extraneous light,
observe sensor for
several days as it
takes time to return
to the correct value
Troubleshooting
Malfunction Cause Remedy
Sensor responds when
it should not
Wind is moving
trees and bushes in
the detection zone
Cars in the street
are being detected
Sudden change in
temperature due
to weather (wind,
rain, snow) or air
expelled from fans,
open windows
Change zone
Change zone
Adjust detection
zone or change site
of installation
Sensor reach has
changed
Differing ambient
temperatures
Use shrouds to
define detection
zone precisely
Red LED flashing
rapidly
Internal fuse
activated
Switch light "OFF"
and "ON" again
after 5 sec.
Technical specifications
Output:
Filament bulbs, 1000 W max., operating on 230 V AC
Fluorescent lamp, 500 W max., at cos j = 0.5,
inductive load at 230 V AC
6 x 58 W each max., C ≤ 132 µF
operating on 230 V AC
*1)
Voltage: 230 – 240 V, 50/60 Hz
Angle of coverage: 360° with 90° angle of aperture and
sneak-by guard
Sensor reach:
8 m max. all round (mounted at a height of 1.75 – 2 m)
Time setting: 5 sec. – 15 min.
Twilight setting: 2 – 2000 lux
Programme setting: 4 function programmes geared to practical
requirements
ON time: selectable (4 hours) provided Switch in
mains power supply lead
Enclosure: IP 54
Temperature range: -20 °C to +50 °C
GB
*1)
Fluorescent lamps, low-energy bulbs, LED lights with electronic ballast (total capacity
of all connected ballasts below the value specified).
IS NM 360_Osteuropa Vs_D.indd 19 15.10.12 11:22