User manual
1716
Troubleshooting
Sensor without power
■ Fuse faulty, not
switched "ON",
break in wiring
■ Short circuit
■ Fit new fuse; switch
"ON" mains switch;
check wiring with
voltage tester
■ Check connections
Sensor will not switch
"ON"
■ Twilight control set
to night-time mode
during daytime
operation
■ Bulb faulty
■ Mains switch "OFF"
■ Fuse faulty
■ Detection zone not
properly targeted
■ Internal electri-
cal fuse has been
activated (red LED
flashing rapidly)
■ Re-adjust
(control h)
■ Change bulb
■ Switch "ON"
■ Renew fuse,
check connection
if necessary
■ Re-adjust
■ Switch sensor
"OFF" and "ON"
again after approx.
5 sec.
Malfunction Cause Remedy
Sensor will not
switch "OFF"
■ Continued move-
ment in detection
zone
■ Sensor unit is not
properly engaged
■ Check detection
zone and re-adjust
if necessary
■ Lightly press sensor
unit to clip it into
place
Sensor doe not switch
"OFF" at around
midnight
■ External light
source (e.g. another
motion detector or
light) inactivating
the sensor
■ Shade sensor from
extraneous light,
observe sensor for
several days as it
takes time to return
to the correct value
Troubleshooting
Malfunction Cause Remedy
Sensor responds when
it should not
■ Wind is moving
trees and bushes in
the detection zone
■ Cars in the street
are being detected
■ Sudden change in
temperature due
to weather (wind,
rain, snow) or air
expelled from fans,
open windows
■ Change zone
■ Change zone
■ Adjust detection
zone or change site
of installation
Sensor reach has
changed
■ Differing ambient
temperatures
■ Use shrouds to
define detection
zone precisely
Red LED flashing
rapidly
■ Internal fuse
activated
■ Switch light "OFF"
and "ON" again
after 5 sec.
Technical specifications
Output:
Filament bulbs, 1000 W max., operating on 230 V AC
Fluorescent lamp, 500 W max., at cos j = 0.5,
inductive load at 230 V AC
6 x 58 W each max., C ≤ 132 µF
operating on 230 V AC
*1)
Voltage: 230 – 240 V, 50/60 Hz
Angle of coverage: 360° with 90° angle of aperture and
sneak-by guard
Sensor reach:
8 m max. all round (mounted at a height of 1.75 – 2 m)
Time setting: 5 sec. – 15 min.
Twilight setting: 2 – 2000 lux
Programme setting: 4 function programmes geared to practical
requirements
ON time: selectable (4 hours) provided Switch in
mains power supply lead
Enclosure: IP 54
Temperature range: -20 °C to +50 °C
GB
*1)
Fluorescent lamps, low-energy bulbs, LED lights with electronic ballast (total capacity
of all connected ballasts below the value specified).
IS NM 360_Osteuropa Vs_D.indd 19 15.10.12 11:22