IS 360 W IS 360 B English Installation Instructions Ceiling Mount Outdoor Occupancy Sensor Français Consignes d’installation Outdoor Sensor with Dual Lampholders RoHS Compliant Made in Romania
3 WARNING Product Overview • Turn power off at the circuit breaker before installing the sensor • Sensor must be installed and used in accordance with appropriate electrical codes and regulations • Installation by a qualified electrician is recommended 120V 60Hz PIR IP54 360° Ceiling mount IS 360 Installation Overview In this package Needed for installation • IS 360 sensor • For exterior installation: 1 NEMA watertight round 4-inch junction box • Accessory pack (2 fastening screws, 2 anchors,
5 4 Mounting Operation Installation Ensure use of the correct enclosure and confirm power is off at the circuit breaker. Junction box Mounting plate 1 Sensor housing 2 Fastening screw Housing cover 4 Decorative ring 3 • Remove housing cover. Press the two indentations on side of housing cover, turn counter-clockwise and pull. • Backout the 2 fastening screws; separate sensor housing from mounting plate.
6 7 Setup & Commissioning (cont’d) Troubleshooting Coverage size Malfunction With an installation height of 8 to 10 feet, maximum reach is up to 40 ft. If needed, the detection zone can be adjusted (see below). No power at the sensor Typical mounting height for the IS 360 is 8 to 10 feet Lights do not switch ON 15 ft 15 ft 15 ft breaker has tripped; light switch is in OFF position Shrouds, supplied with each unit, snap in place, allowing users to adjust coverage as needed.