Use and Care Manual

5
INSASGH1015
TROUBLE SHOOTING
N.B. If you do not solve the problem after checking these points, cut off the power supply at the main electrical panel
and contact our customer service (see the “Limited warranty” section to obtain the phone numbers).
PROBLEM DEFECTIVE PART OR PART TO CHECK
The unit does not work
Defective thermostat or wrong thermostat setting
Open circuit breaker or fuse
The thermal protection has been activated
Faulty connections
The unit runs continuously
Defective thermostat or wrong thermostat setting
Heat losses higher than the unit capacity
The enclosure is extremely hot
Defective thermal protection
Defective motor
Blocked air vents
The desired room temperature cannot be reached
One or more elements are defective
Defective thermostat or wrong thermostat setting
Voltage lower than that written on the nameplate
Heat losses higher than the unit capacity
Room overheating
Defective thermostat or wrong thermostat setting
The unit cycles under control of the thermal protection
Blocked air vents
The breaker trips when the heater is turned on
Faulty connections
Voltage higher than that written on the nameplate
REF # PART # DESCRIPTION
1 PROT-005 THERMAL PROTECTION L175-40F
2 MO-016 MOTOR 208/240V 50/60HZ 0.4A (W/RING)
3 BLA-005 FAN BLADE 9” 26° 5 BLADES .250 HOB CCW
4 PL-240 PILOT LIGHT 250V (RED)
REPLACEMENT COMPONENT LIST
MAINTENANCE, TROUBLESHOOTING
AND REPLACEMENT COMPONENTS
1
2
3
4
ITEM 4 : PL-240
PILOT LIGHT 250V (RED)
LUMIÈRE TÉMOIN
250V (ROUGE)
N.B. In order for the warranty to be valid, the unit must be
cleaned regularly.
Cut off power supply at circuit breaker/fuse before cleaning the unit.
Use a soft rag for dusting. When cleaning, use only a damp rag and
non-abrasive dish soap. Do not use abrasive or chemical cleaners
because they can damage the nishing. If the unit is used in a very
dusty location, use a vacuum brush to remove dust and other foreign
objects from the grills.
Do not use cleaning products identied with these symbols:
N.B. Note that there is electrical current to the unit even if the
thermostat is off. Meaning that there is a risk of electric shock
as long as the unit is energized.
MAINTENANCE