USER’S GUIDE ASIRH SERIES INFRARED RADIATOR HEATER REPLACEMENT COMPONENT LIST INCLUDED RADIATEUR INFRAROUGE For further information or to consult this guide online, please visit our web site: www.stelpro.
SPECIFICATIONS IMPORTANT INSTRUCTIONS AVERTISSEMENT Before installing and operating this product, the user and/or installer must read, understand and follow these instructions and keep them handy for future reference. If these instructions are not followed, the warranty will be considered null and void and the manufacturer deems no further responsibility for this product.
TECHNICAL DRAWINGS TECHNICAL DRAWINGS 21 1/4" 540mm 1500 W + 2000 W MODELS 12 1/4" 311mm AXIS 14 15/16" 380mm TOP 21 5/8" 549mm 5 5/8" 143mm 2 11/16" 69mm 19" 483mm 2 5/8" 66mm 10" 254mm 5" 127mm FRONT 4000 W MODEL SIDE 21 1/4" 540mm 12 1/4" 311mm AXE 14 15/16" 380mm TOP 21 5/8" 550mm 19" 483mm 5 5/8" 143mm 2 11/16" 69mm 2 5/8" 66mm 15 7/8" 403mm 7 15/16" 202mm SIDE FRONT 21 1/4" 540mm 4180 W + 6000 W MODELS 12 1/4" 311mm AXE 14 15/16" 380mm TOP 21 5/8" 550mm 19" 483mm 5 5/8" 143mm
INSTALLATION DIMMER-TIMER AND CONTROLS (NOT INCLUDED) SIRHC402-1 DIMMER The 1500 W at 120 V, 2000 W / 1600 W at 240 V / 208 V & 4000 W / 3200 W at 240 V / 208 V units can be controlled by the Stelpro electronic dimmer that is equipped with a timer (not included). The 1500 W at 120 V, 2000 W / 1600 W at 240 V / 208 V & 4000 W / 3200 W at 240 V / 208 V units can also be controlled by an independant switch that is not offered by Stelpro.
INSTALLATION 4000 W / 3200 W AT 240 V / 208 V & 4200 W AT 347 V UNITS It is very important to respect the clearance from flammable material, as mentioned below. INSTALLATION MURALE WALL INSTALLATION All flammable items must be at least 48” (1.22 m) from the front of the unit.
INSTALLATION, OPERATION & MAINTENANCE REPLACEMENT OF AN INFRARED LAMP Handle carefully; there are sharp aluminum pieces inside. 2 1. Before installing or replacing an infrared lamp, switch off the appropriate circuit breaker in the electrical service panel. 2. Remove the back cover (1). 3. Before disconnecting the defective lamp, please note how the wires are fixed to the ceramic terminal blocks. It is very important to connect the lamps in the same way as before (parallel or series connection). 3 1 4.
REPLACEMENT COMPONENT LIST REPLACEMENT COMPONENT LIST REF.
LIMITED WARRANTY This limited warranty is offered by Stelpro Design inc. (“Stelpro”) and applies to the following products made by Stelpro: ASIRH models. Please read this limited warranty carefully. Subject to the terms of this warranty, Stelpro warrants its products and their components against defects in workmanship and/or materials for the following period from the date of purchase: 3 years. This warranty applies only to the original purchaser; it is non-transferable and cannot be extended.