Instructions / Assembly
INSASIRH0117
4
DIMMER-TIMER AND CONTROLS (NOT INCLUDED)
SIRHC402-1 DIMMER
The 1500 W at 120 V, 2000 W / 1600 W at 240 V / 208 V & 4000 W / 3200 W at 240 V / 208 V units can be controlled by
the Stelpro electronic dimmer that is equipped with a timer (not included).
The 1500 W at 120 V, 2000 W / 1600 W at 240 V / 208 V & 4000 W / 3200 W at 240 V / 208 V units can also be controlled
by an independant switch that is not offered by Stelpro.
The 4200 W at 347 V & 6000 W / 4800 W at 240 V / 208 V units can only be controlled by an independant switch that is
not offered by Stelpro.
For other types of controls: The power to the units can be reduced using appropriate controls. The controls must be able to handle inductive and
resistive loads. In addition, they must have circuits to regulate the start-up current, since this type of unit requires a high start-up current.
+
-
N.B. Cut off power supply at circuit breaker/fuse before proceed-
ing to the installation and wiring connections. This product must
be connected by a certied electrician, according to the electri-
cal and building codes effective in your region.
To reduce the risk of re, do not store or use gasoline or other
ammable vapors and liquids in the vicinity of the heater. Do not
mount in contact with combustible material. Do not mount in
close proximity to another unit.
The unit can be installed anywhere from 2.5 meters (8 feet) to 6
meters (20 feet) from the oor.
FOR THE BEST POSSIBLE RESULTS, THE FOLLOWING
RECOMMENDATIONS SHOULD BE RESPECTED WHEN
INSTALLING THE INFRARED RADIATORS:
- Unit must be horizontally mounted.
- If the support provided is not sufcient for the clearance distance
required, Stelpro offers an optional extensible support (product
code: KIT-SIRH-SUP1) which can be adjusted to obtain distances
ranging from 20 in. (51 cm) to 34 in. (86 cm).
- The unit can be installed on wood surfaces, gypsum, metal, brick,
stone or concrete.
- It is very important to respect the minimum clearance distance to
prevent re or damages to your property.
- This device emits very high radiant heat forward, when in close
proximity never point the front of the unit directly at a wall or ceiling,
doing so could also cause re or damage to your property. Once
the correct position is established, in order to prevent unwanted
movement of the unit, make sure the handles are securely tightened
with the spring washers in place.
- The unit must be rmly mounted to the mounting area using the
appropriate screws or any other mounting device (not included).
INSTALLATION
DETAIL A
1500 W AT 120 V AND 2000 W / 1600 W AT 240 V / 208 V UNITS
It is very important to respect the clearance from ammable material, as mentioned below.
All ammable
items must be
at least 30”
(0,76 m) from
the front of the
unit.
= 25 à 60°
minimum
12"
[305 mm]
minimum
12"
[305 mm]
minimum
18"
[460 mm]
VUE DE CÔTÉ
minimum
18"
[460 mm]
minimum
12"
[305 mm]
minimum
18"
[460 mm]
12"
[305 mm]
VUE DE CÔTÉVUE DE FACE
INSTALLATION MURALE INSTALLATION AU PLAFOND
VUE DE CÔTÉ
H
H
WALL INSTALLATION CEILING INSTALLATION
SIDESIDE SIDEFRONT
INSTALLATION
- When installing, make sure that the mounting surface behind the
unit is strong enough to support the weight of the bracket and the
unit. On a drywall/gypsum surface, thin wood or thin covering, you
need to ensure that the fasteners are securely anchored into wall
studs or ceiling joists.
- Unit must be mounted to the wall or ceiling following the illustrations
here.
- Adjust the installation angle with the angles displayed on the sides
of the support and the embossed marks (DETAIL A). Tighten the
handles of the unit in order to secure the chosen angle.