Use and Care Manual
4
INSASOR1016
INSTALLATION OF WALL RACK
1. Release the unit from the wall rack by depressing the hooks.
2. Place the wall rack on the oor and against the wall where the unit is to be installed.
3. Using a pencil and the holes provided in the wall rack, make marks on both sides of the rack at the desired height for the bottom of the
wall rack. Although not mandatory, please note that the positioning of the unit makes installation easier with the use of the pre-cut holes.
4. Securely fasten the rack to the wall, making sure that it is level. When drilling into the wall, make sure not to damage any electrical
wiring or other hidden objects.
N.B. The wall where you install this rack must be straight so that the bracket remains at once installed without having to
apply any pressure. If the rack is not at once installed, the hooking mechanism could be compromised and the convector
could unexpectedly release from its rack.
INSTALLATION OF CONVECTOR
ON WALL RACK
1. Insert the lower hooks of the wall bracket into the
lower slots on the rear of the convector.
2. Engage the hooks of the wall rack into the upper
slots on the rear of the convector.
3. Push on the convector to make sure that it is fully
engaged with the wall rack. You should hear the
hooks engage when pressure is applied to the
upper front of the convector.
THE BOTTOM OF THIS UNIT MUST BE INSTALLED AT LEAST 4 INCHES (10.2 CM) FROM THE FLOOR.
The supply wires must be connected in accordance with all effective
building and electrical codes. The bare (ground) wire must be
connected to the green wire in the convector using an appropriate
wire nut. The supply wires (from the electrical panel) must be
connected to the wires labelled “L1” and “L2” in the convector using
appropriate wire nuts.
N.B. This product must be connected by a qualied electrician
as per the wiring diagram to the right and in accordance with
building and electrical codes effective in your area.
Unit
Electrical
box
Connector (marette)
L1 (black)
L2 (red)
Ground (green)
#
#
#
INSTALLATION & ELECTRIC WIRING
ELECTRIC WIRING
N.B. Cut off power supply at circuit breaker/fuse before proceeding with the installation. To reduce the risk of re, do not store
or use gasoline or other ammable vapors and liquids in the vicinity of the heater. Do not mount in contact with combustible
material. Do not mount in close proximity to another unit.
CAUTION – High temperature; risk of re. Keep electrical cords, drapery, furnishings, and other combustibles at least 3 feet (0.9 m)
from the front of the heater and away from the side and rear.
- The unit should be installed at least 4 in. (10.2 cm) from the oor and 6 in. (15 cm) from adjacent walls.
- Before operating the unit, make sure that both the air inlet (bottom) and the air outlet (front) are free from obstruction.