Instructions / Assembly

7
A
C
B
L1
L2/N
GND
A
A
Warning: Use copper or aluminium wires only.
Use supply wires suitable for 194 °F.
1. If needed, strip the power cable wires with a wire stripper.
2. Connect the fan heater and power supply wires according to the
connection diagram with the supplied connection caps [A]. Tighten
caps on the wires to make sure the connections are secure.
3. Connect the grounding wire rmly with the green screw [B] pro-
vided at the back of the back box. The grounding screw can be
moved to position [C], if required.
4. Store all the wires in the back box.
6
CONNECTING THE WIRING
* Models WITH thermostat ONLY
Models WITHOUT thermostat ONLY
MOTOR
ELECTRONIC
THERMOSTAT*
THERMAL
FUSE
THERMAL
PROTECTION
TOP VIEW
1. Insert the fan heater’s back box in the
opening you’ve made in the wall, making
sure it is level.
5
ATTACHING THE BACK BOX TO THE WALL
2. According to your
installation, screw*
the box to the wall
stud using two
mounting holes [A].
NOTE: If the wall nishing is not ins talled
yet, make sure you position the box at
the correct depth so that it rests on the
surface once work is complete.
For 1/2 inch thick nishing, you can fold
the side tabs and install directly on the
stud. For other thicknesses, align the stud
with the corresponding perforated marks.
WALL FINISHING
* Screws not included
ELECTRICAL DIAGRAM OF THE DEVICE
CONNECTION DIAGRAM
ELEMENT
ELEMENT
JUMPER