Instructions / Assembly

15
WARNING: Cut o the power at the breaker or fuse
before cleaning the unit. High voltage and the risk
of electric shock are present in the unit even if the
thermostat is set to o. Therefore, you can receive
an electrical shock as long as the unit is under power.
Over time, cigarette smoke may cause the outlet grill to yellow.
The best way to prevent yellowing is to clean the unit regularly.
Dust the front panel with a soft cloth and clean it with a damp
cloth only. If you use cleaning products, they could cause the
heater to yellow.
If the unit is installed in a very dusty location, use the dust brush
of a vacuum cleaner to remove dust and other foreign objects.
When maintaining the product, never use:
A brush or metal scrubbing pad
Chlorine
Abrasive cleaning products
Hydrochloric acid-based products such as bleach
Any other cleaning products that bear the following
symbols:
MAINTAINING THE FAN HEATER
TECHNICAL INFORMATIONS
FOR THE WARRANTY TO BE VALID, THE FAN HEATER’S AIR INLET AND OUTLET MUST BE CLEANED REGULARLY.
ITEM DESCRIPTION
Purpose of Control
Thermostat
Degree of Protection by enclosure
IP20
Nature of Supply
Control for AC
Type of Load Controlled
Circuit suitable for either a resistive load or for an inductive load with a power factor not
less than 0.6 or a combination of both.
Type 1 of Type 2 action + Additional features
Type 1.Y: ELECTRONIC DISCONNECTION on OPERATION
Control Pollution Degree
PD2
Unique Type Reference (UTR),
Rated Voltage / Watts
UTR – ST294 with CIR054:
120Vac / 1000W
120Vac / 1500W
208Vac / 1000W
208Vac / 2000W
240Vac / 1000W
240Vac / 2000W
UTR – ST295 with CIR054:
120Vac / 1000W
120Vac / 1500W
208Vac / 1000W
208Vac / 2000W
240Vac / 1000W
240Vac / 2000W
Frequency
60Hz
Intended Delivery Location
Control intended to be delivered exclusively to the equipment manufacturer (STELPRO).
It will never be sold seperatly as a replacement kit.
Overcurrent protective device external
to the control
A breaker is used as the protective device.
For 120Vac, use a Single Pole 15A breaker;
For 208Vac and 240Vac, use a Double Pole 20A breaker;
Operating Temperature
-20°C to 50°C
Storage Temperature
-40°C to 50°C