OWNER'S MANUAL ASSOS...WCW ASSOS...W ASSOS...MW INS-ASSOS_0918 IT’S GOT BRAINS. AND LOOKS. THANK YOU FOR YOUR PURCHASE! QUESTION? PROBLEM? CONTACT STELPRO CUSTOMER SERVICE. TÈME QUAL ITÉ SYS THIS UNIT COMPLIES WITH CSA STANDARDS EG IÉ - R ISTERE D TIF Q ER STEM Y SY LIT UA C WWW.STELPRO.COM CONTACT@STELPRO.
IMPORTANT INSTRUCTIONS RISK OF FIRE, ELECTRIC SHOCK, BODILY INJURY AND DAMAGE Before installing and using this product, you must read and understand these instructions and keep them for future reference. If the installer and the user do not follow these instructions, the manufacturer cannot be held liable in any way and the warranty will be null and void.
INSTALLING THE FAN HEATER TO ENSURE A SAFE AND EASY INSTALLATION, TAKE A FEW MINUTES TO READ THIS INSTALLATION GUIDE. WHAT IS IN THE BOX TOOLS REQUIRED Level SONOMA STYLE Wall fan heater Flat screwdriver Phillips screwdriver Tape measure Wire stripper Stud finder Self-adhering spacer 2 Caps Wire clamp Tool to cut drywall or gypsum board 2 Screws (1-1/2") with a head at least 1/4" (6.5 mm) in diameter, suitable for securing the back of the air heater’s cabinet directly to a stud.
WARNING: This product must be installed by a certified electrician according to the electrical and building codes effective in your region. 1 WHERE TO INSTALL YOUR FAN HEATER Make sure that objects or furniture near the heater can withstand the heat it gives off. Install your fan heater in an unobstructed location at least 6 in. off the ground. Do not install the heater on a wall behind a door. TIP: You can access the fan heater’s controls more easily if you install it 12 in. off the ground.
2 CUTTING THE POWER SUPPLY ON OFF To protect yourself from the risk of electric shock, turn off the power to the lead wires from the electrical panel. 3 PREPARING THE SURFACE FOR INSTALLATION IMPORTANT: Models provided without back-box shall be only installed with back-box kit-ASSOBB available at your heater supplier. Do not use any other back-box or retrofit. 7 5/8" 1. L ocate the studs and any other structures that might be inside the wall. 10" 2.
4. Perforate one of the seven pre-cut holes. Choose the hole according to the power cable’s position in the wall and the available space. ATTENTION : Be sure to push in the right hole by placing the back box in the correct direction. The notches must be positioned at the bottom [C]. C 5. P lace the wire clamp [D] in the hole. Insert the power cable through the wire clamp and secure it. D C 6.
5 ATTACHING THE BACK BOX TO THE WALL 2. A ccording to your installation, screw* the box to the wall stud using two mounting holes [A]. 1. I nsert the fan heater’s back box in the opening you’ve made in the wall, making sure it is level. A A NOTE: If the wall finishing is not installed yet, make sure you position the box at the correct depth so that it rests on the surface once work is complete. TOP VIEW For 1/2 inch thick finishing, you can fold the side tabs and install directly on the stud.
7 ATTACHING THE MECHANICAL HOUSING TO THE BACK BOX 1. Put the mechanical housing [A] in the back box by inserting it into the bottom hooks [B] provided for this purpose. 2. P ivot the mechanical housing toward the wall. Be careful not to trap the wires or caps. 3. S ecure with the screws set aside in step 4.2. A B 8 ATTACHING THE FRONT PANEL 1. F or the models with built-in thermostat, clip the connector [A] under the thermostat and pass the cable under the hook [B] (cable strain relief).
2. P ress the top of the front panel against the wall, keeping it slightly tilted [C] and centered with respect to the mechanical housing. C 3. Carefully slide the front panel down until the hooks behind the front panel [D] are engaged and then pivot it toward the wall. D 4. C heck that the screw at the bottom of the unit is inserted in the front panel’s slot [E]. Tighten the screw to secure the front panel.
USING THE FAN HEATER WARNING: Before using your fan heater, make sure that it has been installed by a certified electrician in accordance with the electrical and building codes in your area. Do not operate without front panel. The following sections outline how to control the fan heater with its built-in electronic thermostat (ASSOS.....MW and ASSOS.....W models).
DEFINE THE FAN HEATER’S TEMPERATURE SETPOINT 3. W hen the desired temperature setpoint is reached, release the button. The temperature will flash for 3 seconds before being saved. The built-in thermostat has two buttons that let you choose the temperature setpoint. By default, the temperature setpoint is 66 °F. Once the temperature setpoint is saved, the ambient temperature will display on the screen. 1. Press or once. The temperature setpoint will flash to indicate it can be modified.
Connecting the thermostat to your Zigbee network Disconnecting the thermostat from the Zigbee network The fan heater’s thermostat is compatible with the Zigbee smart home protocol. To control it, you must connect it to your network from the MAESTRO smart controller-thermostat or a Zigbee-compatible controller. You may need to disconnect the thermostat from your Zigbee network, if you change controllers or channels, for example. 1.
Activating or deactivating open window detection The thermostat can detect if a window is open in the room where the fan heater is located. It will automatically adjust the temperature setpoint to 45 °F to avoid heating the room unnecessarily. To activate or deactivate open window detection: 1. Access menu 5, Open window detection . 2. S elect ON to activate or OFF to deactivate open window detection. When an open window is detected, the icon and buttons flash, then turn blue. 3.
TROUBLESHOOTING THE FAN HEATER The following table outlines the most common issues and alerts you could experience with your fan heater. If your problem is not listed in the table below or the proposed solution does not solve the problem, turn the power off and contact our customer service team. WWW.STELPRO.COM CONTACT@STELPRO.COM 1-844-STELPRO PROBLEM/ALERT POSSIBLE CAUSE AND SOLUTION PROBLEM/ALERT POSSIBLE CAUSE AND SOLUTION The fan heater is not operational after installation.
MAINTAINING THE FAN HEATER FOR THE WARRANTY TO BE VALID, THE FAN HEATER’S AIR INLET AND OUTLET MUST BE CLEANED REGULARLY. When maintaining the product, never use: WARNING: Cut off the power at the breaker or fuse before cleaning the unit. High voltage and the risk of electric shock are present in the unit even if the thermostat is set to off. Therefore, you can receive an electrical shock as long as the unit is under power. Over time, cigarette smoke may cause the outlet grill to yellow.
STELPRO LIMITED WARRANTY This limited warranty is offered by STELPRO Design inc. (“STELPRO”) and applies to the following product made by STELPRO: ASSOS model. Please read this limited warranty carefully. Subject to the terms of this warranty, STELPRO warrants its products and their components against defects in workmanship and/or materials for the following periods from the date of purchase: 5 years (3 years on electronic components).