Simply rapid.
Merckoquant ® COMBINING ULTIMATE SIMPLICITY WITH SPEED Test strips are true high-tech products – a mobile laboratory on just a few square millimeters of backing. Merckoquant® test strips are suitable for the semiquantitative detection of ions and of inorganic and organic substances. They can be used to measure concentrations from as low as 1 or 10 mg/l as the case may be right up to the g per liter range.
PRODUCT RANGE Merckoquant® test strips allow more than 30 different identification tests and semiquantitative determinations to be performed. For some substances we even provide several different test strips to cover various detection ranges, so that in all our range consists of more than 40 different Merckoquant® tests. The standard pack contains 100 test strips in an aluminium tube fitted with a desiccant-filled stopper. User information is provided in 4 languages.
POINTS TO OBSERVE WHEN HANDLING MERCKOQUANT® PRODUCTS 1. Thoroughly wet the reaction zones on the strip 2. After the prescribed reaction time (10 sec to by briefly (1 sec) dipping them in the solution being max. 2 min) has elapsed, compare the color of tested. Remove excess liquid by stroking the edge the reaction zone with the color scale printed on of the strip against the rim of the sample vessel, or the pack, and read off the concentration. using an absorbent paper towel.
QUALITY ASSURANCE Merck uses certified standard solutions to adjust and check the tests and the faithfulness of the reference colors. These standard solutions are directly traceable to primary reference standards from NIST and PTB, a factor instrumental in assuring the high quality of Merckoquant® test strips. RISK AND SAFETY PHRASES Please read the risk (R) and safety (S) phrases printed on reagent packs. Keep Merckoquant® test strips out of reach of children.
Aluminium Ammonium Arsenic Arsenic Ascorbic acid Blank test strips Calcium Carbonate hardness Chloride Chlorine Chlorine Chromate Cobalt Copper Cyanide Fixing bath Ag/pH Formaldehyde Iron Lead Manganese Molybdenum Nickel Nitrate Nitrite Nitrite Peracetic acid Peracetic acid Peracetic acid Peroxide Peroxide Peroxide pH Phosphate Potassium Quaternary ammonium compounds Sulfate Sulfite Tin Total hardness Total hardness Zinc 6 Sea wa ter Mi lk, dai ry p Mi ro ner al w ducts a Sw ter imm , na tur ing al s Dri
Pag e o. .N Ord Me Me tho asu d rin gr an ge OVERVIEW 10 - 250 mg/I Aurin tricarboxylic acid 1.10015.0001 8 Aluminium 10 - 400 mg/I Nessler 1.10024.0001 8 Ammonium 0.02 - 3 mg/l Modified Gutzeit method 1.17926.0001 8 Arsenic 0.005 - 0.5 mg/I Modified Gutzeit method 1.17927.0001 8 Arsenic 50 - 2000 mg/I Phosphomolybdenum blue 1.10023.0001 9 Ascorbic acid 1.11860.0001 9 Blank test strips 10 - 100 mg/I Glyoxalbishydroxyanil 1.10083.
Al3+ ALUMINIUM Ord. No. 1.10015.0001 Merckoquant® Aluminium Test The following concentrations of foreign ions (in mg/I) do Presentation 100 test strips and reagents not interfere with the determination. Graduation 0 – 10 – 25 – 50 – 100 - 250 mg/I AI3+ Ag+ 1,000 Fe2+/3+ 50 PO43- Aluminium compounds are used as flocculating agents in water works, in swimming Ca 1,000 [Fe(CN)6] 1,000 S pools, paper mills, etc.
ASCORBIC ACID Ord. No. 1.10023.0001 The following concentrations of foreign ions (in mg/l) do Merckoquant® Ascorbic acid Test not interfere with the determination.
Cl - CHLORIDE Ord. No. 1.10079.0001 Merckoquant® Chloride Test The following concentrations of foreign ions (in mg/l) do Presentation 100 test strips not interfere with the determination. Graduation 0 - 500 - 1000 - 1500 - 2000 - 3000 mg/l Cl Ag+ Cl2 75 3+ Hg2+ - Chloride ions occur in all natural waters. Their concentration depends on geological Al factors and the general local situation.
CrO22- CHROMATE The following concentrations of foreign ions (in mg/l) do Merckoquant® Chromate Test not interfere with the determination. Presentation 100 test strips and reagent Graduation 0 - 3 - 10 - 30 - 100 mg/ l CrO42- Ag+ Al 1,000 3+ F- 1,000 NO2- 1,000 2+ - Ord. No. 1.10012.0001 1,000 Fe 1 NO3 1,000 The Chromate Test can be used to monitor waste water discharged from electro- Ba2+ 1,000 Fe3+ 25 PO43- 1,000 plating and pickling plants, tanneries, etc.
Ag+ FIXING BATH (SILVER and pH) Ord. No. 1.10008.0001 Merckoquant® Fixing bath Test The following concentrations of foreign ions (in mg/l) do Presentation 100 test strips not interfere with the determination. Graduation 0 - 0.5 - 1 - 1.
Pb2+ LEAD Ord. No. 1.10077.0001 The following concentrations of foreign ions (in mg/l) do Merckoquant® Lead Test not interfere with the determination.
NO3- NITRATE Ord. No. Merckoquant® Nitrate Test 1.10020.0001 Presentation 100 test strips Graduation 0 - 10 - 25 - 50 - 100 - 250 - 500 mg/ l NO3- The following concentrations of foreign ions (in mg/l) do not interfere with the determination. Ag+ Merckoquant® Nitrate Test Presentation Graduation 1.10020.
NO2- NITRITE Ord. No. The following concentrations of foreign ions (in mg/l) do Merckoquant® Nitrite Test not interfere with the determination.
O22 PEROXIDE Ord. No. Merckoquant® Peroxide Test 1.10011.0001 Presentation 100 test strips Graduation 0 - 0.5 - 2 - 5 - 10 - 25 mg/l H2O2 The following concentrations of foreign ions (in mg/l) do not interfere with the determination. CrO42- Merckoquant® Peroxide Test 1.10011.0002 [Fe(CN)6] Hg+ Presentation 25 test strips Graduation 0 - 0.5 - 2 - 5 - 10 - 25 mg/l H2O2 Merckoquant® Peroxide Test 10 3-/4- IO4- 40 - 10 MnO4 2 250 S2O82- 20 VO3- 5 1.10081.
PO43- PHOSPHATE Ord. No. 1.10428.0001 The following concentrations of foreign ions (in mg/l) do Merckoquant® Phosphate Test not interfere with the determination. Presentation 100 test strips and reagent Graduation 0 - 10 - 25 - 50 - 100 - 250 - 500 mg/l PO43- Fe2+/ Fe3+ 250 NO2- 10 1,000 H2O2 100 NO3- 1,000 The Phosphate Test is suitable for determining ortho-phosphate in waste water, soil Ca2+ 1,000 K+ 500 SO32- 1,000 samples, fertilizers and suitably prepared food samples.
SO42- SULFATE Ord. No. 1.10019.0001 Merckoquant® Sulfate Test The following concentrations of foreign ions (in mg/l) do Presentation 100 test strips not interfere with the determination. Graduation 0 - 200 - 400 - 800 - 1200 - 1600 mg/l SO42Al3+ 100 The Sulfate Test is a rapid exploratory test.
TOTAL HARDNESS (SUM OF ALKALINE EARTH IONS) Ord. No. Knowing how hard the water is in a particular area enables Merckoquant® Total hardness Test 1.10025.0001 detergents to be used more economically, thereby cutting Presentation 100 test strips down on pollution. The test can also be used to check the Graduation 3 - 4 - 7 - 14 - 21°d * = ^ 4 - 5 - 9 - 18 - 26 °e efficiency of domestic or industrial water softeners.
5/06 W 242101 Merck KGaA 64271 Darmstadt, Germany Fax: +49 (0) 61 51 72-60 80 E-mail: environmental.analysis@merck.de http://fea.merck.de We provide information and advice to our customers to the best of our knowledge and ability, but without obligation or liability. Existing laws and regulations are to be observed in all cases by our customers. This also applies in respect to any rights of third parties.