User's Manual

Aeris Installation, Service and Troubleshooting Manual
Page | 30
Figure 23
Item Description
1. Air tank Trailer Air Tank
2. Outlet Air Supply of Control Box Attach air lines from Aeris hubcap to “Outlet” side of control box
3. Inlet Air Supply of Control Box Attach air lines from PPV to “Inlet” side of control box
4. Pressure Protection Valve Required; 70 psi minimum closing pressure
5. Air Supply From Tractor Air supply hooked to air tank coming from the tractor compressor
6. Aeris Hubcap Axle Air lines Air line from Aeris hubcap axle air lines hooked to “Outlet” on control box
7. 1/4" Airline “Tee” Fittings 1/4" tube tee air line fittings to hook air lines from axles to air tank
8. Control Box Air lines and electrical wiring run to control box for Aeris system
9. Mini Ball Valve Air shut on/off valve. Must be in ”Open” position for Aeris system to work