Instructions / Assembly
11
9. Repeat to replace the second filter cartridge.
10. Lift the handle, of the system faucet, and lock the faucet in the “ON” position. Slowly open the supply valve, and allow the
system to fill with water.
11. When water begins to flow from the faucet, allow water to run for several minutes until it is clear with no air bubbles. Turn
off the faucet and check between the filter housing and head for leaks.
12. It is recommended when installing a new carbon filter, to allow the water to run for 10 minutes to flush the filter and system
prior to use.
13. Restore power to the water purifier.
LAMP INSTALLATION OR REPLACEMENT BIO-1.5 USING BALLAST NO.10-0518A 120V 50/60HZ
AND USING BALLAST NO.10-0514A 230V 50/60HZ
SAFETY EQUIPMENT REQUIRED TO PERFORM TASK
Figure 7 - Lamp Replacement
1. WARNING: Disconnect power to water purifier, and remove ground connector from the chamber.
2. Remove EASY-OFF
TM
end cap by pulling cap off static gland nut.
3. Pull lamp cord and carefully withdraw lamp approximately 2 inches from chamber. While holding lamp
end, remove lamp socket from exposed lamp end.
4. Carefully withdraw lamp from chamber. Be sure to withdraw lamp straight out without angling
until completely clear of quartz sleeve.
CAUTION: Lamp and quartz sleeve are easily damaged. Exercise care when handling.
5. Reinstall lamp in reverse order.
WARNING: Germicidal ultraviolet rays are harmful to eyes and skin. Do not restore power to water purifier until
lamp and both EASY-OFF
TM
end caps have been properly reinstalled.
6. Reattach the ground connector to the grounding tab of the chamber, and restore power to the system.
Step 1 - Disconnect Power to Water
Purifier and Remove Ground Connector
Step 4 - Remove LampStep 3 - Remove SocketStep 2 - Remove End-Cap