User guide

AccuMeter Controller Chapter 13: The Recipe 89
RECIPE ERROR MESSAGES:
Recipe total not 100%
Recipe cannot run with current feeders
RECIPE CANNOT RUN WITH CURRENT FEEDERS:
This message means that the current recipe cannot be ran at any rate due to the percent entered
and the current feeder calibrations for each feeder. The feeder calibration is related to the auger
size, gearbox ratio, and the material’s bulk density.
This scenario is difficult for most to understand and can best be explained using an example.
Take for example you only have 2 feeders. Each feeder has a motor that can run down to a
minimum speed and up to a maximum speed. This is the physical limitation of the motor and
cannot be altered. At these speeds each feeder will put out a certain amount of material. These
are displayed on the CALIBRATE FEEDER page. In our example feeder 1 is a small auger