Marine Instruments User's Manual

a = yellow to ignition (or D+/L/61)
b = white to field
c = brown to alt D+/62/L/DL
d = 2 x black to alternator neg.
e = split charge diode / relay
f = alternator
g = starter battery
h = domestic battery bank
i = red to domestic battery
j = black/white to battery negative
k = temperature sensor to alternator
l = temperature sensor to battery
INSTALLATON WITH SPLIT
CHARGE DIODE OR RELAY:
a
b
f
k
l
g
i
j
c
d
e
h
Fig 4
temperature sensor cable to battery terminal
starter battery
red to common
yellow to ignition (or D+/L/61)
brown to D+/61/L
2 x black to neg on alt
1 x black white to batt neg
white to Field/DF/F
POS(+)
domestic
battery bank
1
2
COMMON
BOTH
INSTALLATION WITH
A ROTARY SWITCH:
UNIVERSAL ADVANCED DIGITAL+
4 STEP ALTERNATOR REGULATOR
GREEN: HIGH CHARGE RATE ON
YELLOW: TIMER ACTIVATED
RED ONLY : HIGH BATTERY V TRIP
FLASHING RED: HIGH BATTERY TEMP
CE
HELP LINE FOR STERLING POWER PRODUCTS TEL U.K 01905 26166
GREEN: FLOAT MODE
ORANGE: LOW VOLTAGE WARNING
BATTERY TYPE: GREEN: GEL/SEALED
YELLOW: OPEN LEAD ACID
RED: A.G.I.
1 2
ON
1 2
BATTERY TYPE
PROGRAM SELECTOR
SWITCH, INSIDE LID
3 BATTERY TYPE
POSITIONS
GEL
SEALED
L.E.D.
( GREEN )
LEAD
OPEN
L.E.D.
( YELLOW )
A.G.M
L.E.D.
( RED )
ALL L.E.D.S
FLASHING
HIGH
ALTERNATOR
VOLTAGE
TRIP
BATTERY NEG TRIP FAULT
GREEN:HIGH ALT TEMP DISENGAGE
YELLOW:12 V SYSTEM SETUP
GREEN: 24 V SYSTEM SETUP
EXTRA
CONNECTIONS
BLOCK
REMOTE
CONTROL
SOCKET
TERLING POWER PRODUCTS
S
fan
ALT
TEMP
BATTERY
TEMP
D+
SWITCH
ON
1 2
ON
a
b
f
g
j
c
d
e
h
Fig 5
POS(+)
Temperaturesensor
POS(+)
POS(+)
INSTALLATON MIT TRENNDIODE ODER RELAIS:
UNIVERSAL ADVANCED DIGITAL+
4 STEP ALTERNATOR REGULATOR
GREEN: HIGH CHARGE RATE ON
YELLOW: TIMER ACTIVATED
RED ONLY : HIGH BATTERY V TRIP
FLASHING RED: HIGH BATTERY TEMP
HELP LINE FOR STERLING POWER PRODUCTS TEL U.K 01905 26166
GREEN: FLOAT MODE
ORANGE: LOW VOLTAGE WARNING
BATTERY TYPE: GREEN: GEL/SEALED
YELLOW: OPEN LEAD ACID
RED: A.G.I.
ALL L.E.D.S
FLASHING
HIGH
ALTERNATOR
VOLTAGE
TRIP
BATTERY NEG TRIP FAULT
GREEN:HIGH ALT TEMP DISENGAGE
YELLOW:12 V SYSTEM SETUP
ALT
TEMP
BATTERY
TEMP
D+
SWITCH
EXTRA
CONNECTIONS
BLOCK
REMOTE
CONTROL
SOCKET
TERLING POWER PRODUCTS
S
fan
CE
1 2
ON
1 2
ON
1 2
ON
BATTERY TYPE
PROGRAM SELECTOR
SWITCH, INSIDE LID
3 BATTERY TYPE
POSITIONS
GEL
SEALED
L.E.D.
( GREEN )
LEAD
OPEN
L.E.D.
( YELLOW )
A.G.M
L.E.D.
( RED )
GREEN: 24 V SYSTEM SETUP
Temperature-Sensor
light
CE
on/off
beep
1
2
3
4
2
4
3
1
Power Management
with
AMP Hr Counter
Sterling power products
Amp
hr
Amps Volts
14.35 v m Pos 4
37amps 435 a/hrs
Advanced Alternator Regulator
Display and
Diagnostics Panel
Sterling power products
CE
on/off
alarm
light
temp
System
Default
Low voltage warning
System Disengaged
System Trip
System Within Limits
Screen
Help
Bat 14.4v Timer
Alt 15.4v 134m
set up
volts
a = gelb an Zündung+ oder (D+/R/L/DL)
b = weiss = Feld
c = braun an D+/62/L/DL
d = 2 x schwarz an Lima negativ-minus
e = Trenndiode oder Relais
f = Lichtmaschine
g = Starterbatterie
h = Verbraucherbatteriebank
i = rot an plus der Referenzbatterie
j = schwarz-weiss an minus der Referenzbatterie
k = Temperatursensor für die Lichtmaschine
l = Temperatursensor der Referenzbatterie