Granulators Operation and Installation Manual

The upper part of the cutting chamber is protected by the feed
hopper, used to insert material to be granulated while the lower
part is protected by the screen, and screen support. These
components are fixed by a screw knob, unscrewing releases a
safety switch key (Figure 1), which cuts off the electric supply to
the motor, causing the rotor to stop.
The method of opening the granulator has been designed to restrict
operator access, allowing the rotor and all moving knives to stop
completely. To allow operator access more quickly could be
dangerous as it might be possible to make contact with the
granulator knives while they are still rotating.
Figure 1: Safety Switch
1-3-2 Opening the Granulator
The Start/Stop lighted pushbutton provided on the control panel
(Figure 2) is used to operate the granulator. The button must be
pressed to stop the granulator and pulled out to start.
Before performing any maintenance or opening the granulator,
perform the following procedure:
1. Turn off the granulator using the pushbutton provided.
2. Turn the disconnect switch to OFF and lockout power. (If you
cannot lock out power, remove the power fuses in the control
panel.)
3. Tag the machine as Out of Service.
4. Make sure the rotor has come to a complete stop.
Page 13 of 54