RSD Series Installation Guide

Form #43219040
Jan 2014
C) TROUBLESHOOTING CHART
TROUBLE
POSSIBLE CAUSE
SOLUTIONS
Heater is not glowing
red…
The supply gas pressure is too low.
Improper size of gas piping.
The orifice is clogged.
Incorrect orifice size.
Check the manifold gas pressure and
adjust if necessary.
If you are not sure of the performance,
use the NFPA 54 gas pipe sizing table.
Clean the orifice.
See the instructions for correct orifice
size and replace if necessary.
Heater will not
attain the desired
temperature…
There is insufficient heat in the building
for heat loss (i.e., not enough heaters).
The thermostat sensing bulb is
incorrectly placed.
The thermostat is out of calibration.
Conduct heat loss and add heaters or
other source of heat as necessary.
Reposition as necessary for proper
operation. NOTE: The sensing bulb
should be shielded from direct radiation
to prevent short cycling of the heater.
Recalibrate (if possible) or replace.
Flames flaring up,
outside of emitter
surface…
The gas pressure is too high.
Incorrect orifice size.
Incorrect type of gas supplied to the
heater.
Not enough combustion air.
Check the manifold gas pressure and
adjust if necessary.
See instructions for correct orifice size
and replace if necessary.
Check the nameplate to identify the
correct type of gas the heater is equipped
to operate.
Clean the emitter with compressed air.
17