RSD Series Installation Guide

Form #43219040
Jan 2014
6) R (B,S,M) D SERIES DIMENSIONS
7) HANGING
The heater can be mounted with the reflector horizontal or angled up to 35º from horizontal. When the heater is to be angle
mounted, make sure the gas manifold assembly is on the lower side of the heater. Coil chains (No. 2 or larger) or rigid supports
may be used to mount the heater, which must be suspended from a permanent structure with adequate load capacity. The gas
manifold assembly tube must be level, and for angled mounting, it must be at the LOWER end of the heater. All “S” hooks and
eyebolts must be manually crimped closed by the installer.
7