Installation Guide

DUCT
3. ATTACH DAMPER/DUCT CONNECTOR
Snap the damper/duct connector onto the fan housing. The connector must be flush with the top of the housing, and the
damper flap should fall closed.
4. INSTALL ROUND DUCTWORK
Connect the round ductwork (not included) to the damper/duct connector, and run the ductwork to a roof or wall cap
(not included). Using tape (not included), secure all the ductwork connections so that they are air tight.
ASSEMBLY INSTRUCTIONS
CONNECT ELECTRICAL WIRING
INSTALL GRILLE
3
Insulated flexible duct is recommended for the quietest possible installation. If rigid duct is used, a short (1-3 feet)
section of insulated flexible duct will ensure quiet operation.
Run 120 V AC house wiring to the location of the fan. Use only UL-approved connectors (not included) to attach the house wiring to the wiring plate. Refer to the wiring
diagram, and connect the wires as shown.
FAN
FAN
LIGHT
SWITCH BOX
BLK
WHT
D
Low CFM
switch
S
elay time
Preset switch
Fan
N
LED
Sensor
and LED
Light
GRD
UNIT
SWITCH
SWITCH
BLK
WHT
LINE
IN
LED NIGHT
CONTROL
CIRCUIT
BRN
UNIT
BLACK(BLK)
LED NIGHT
LIGHT
SWITCH BOX
FAN
120V AC LINE IN
GROUND (GRD)
BROWN(BRN)
WHITE (WHT)
WIRE PANEL
RECEPTACLE
For model SED110
For model SED110M
UNIT
BLACK (BLK)
SWITCH BOX
SWITCH I
POWER SUPPLY
120V AC
GROUND (GRD)
WHITE (WHT)
FAN
RECEPTACLE
FAN
WIRE
PANEL
BRN
BLK
SWITCH I
SWITCH II
SWITCH II
BROWN (BRN)
Install ceiling material to complete the ceiling construction. Then, cut around the fan housing.
First insert the sensor plug into the plug base on the power box, and then
install the grille (for model SED110M ).
To attach the grille assembly to the fan housing, pinch the grille springs on the sides of the grille
assembly, and position the grille into the housing with the grille springs in the appropriate slots.
Push the grille assembly towards the ceiling to secure.