User's Manual

USING INTERNAL MENU COMMANDS
©
©©
© RF Innovations Pty Ltd, 1998 Page: 33
234839, Revision 2.2
*** Hayes Command Control Menu ***
Main Port: Hangup on DTR Dropped, Echo is ON, Response is ON
Escape character = + Escape guard time = 1000(ms)
Connect Timeout = 10000(ms)
(C) Connect Timeout
(X) Escape character (ie +)
(G) Escape guard time
(H) Hangup on DTR (low)
(Z) Hangup on DTR Dropped
(L) Local on DTR (low)
(I) Ignore DTR
(E) Echo (ON/OFF)
(R) Modem returns response codes (ON/OFF)
(D) Set to Defaults
(Esc) Previous Menu
Enter Choice:
Figure 6-19 Hayes Command Control Menu
(C) Connect Timeout
This is the wait time for “
CONNECT
”, which is the time the radio will wait for a valid connection.
To set the Connect Timeout, press (C). The following will be displayed:
Connect Timeout value in milliseconds (0-60000): 10000
This time can be set between 100-30000ms. The default is 10000ms
(X) Escape character (ie +)
Allows the escape character to be changed. This is the character that is used in the escape sequence to
hang-up the modem. The escape sequence consists of the escape character being typed three times,
with a set communication-free periods of time before and after the sequence.
To set the Escape Sequence Character, press (X). The following will be displayed:
Enter new escape character: +
The default is ‘+’.
(G) Escape guard time
The escape guard time is the time before and after the escape sequence has been entered that no activity
is allowed on the data line. Otherwise the escape sequence will be ignored.
To set the Escape Guard Time, press (G). The following will be displayed:
Escape guard time value in milliseconds (50-10000): 1000
The range of values allowed is between 50 and 10000ms. The default is 1000ms.