User Manual
SWITCH SETTINGS
Volume - High (105 dB) at 1 ft. ON*
Volume - Low (95 dB) at 1 ft. OFF
Duration - 30 Second Alarm OFF OFF
Duration - 180 Second Alarm OFF ON
Duration - Continuous Alarm ON* OFF*
Duration - Annunciator Mode ON ON
Trip - Immediate OFF*
Trip - 15 Second Delay ON
Arming - Immediate ON*
Arming - 15 Second Delay OFF
FEATURE JP2 JP3 JP4 JP5 JP7
*Factory Settings
Note: Slide black lever to desired ON/OFF
position as labeled on circuit board.
Printed in USA
Safety Technology International, Inc.
2306 Airport Road • Waterford, Michigan 48327-1209
Phone: 248-673-9898 • Toll Free: 800-888-4784
Fax: 248-673-1246 •
www.sti-usa.com
Safety Technology International (Europe) Ltd.
Unit 49G Pipers Road • Park Farm Industrial Estate • Redditch
Worcestershire • B98 0HU • England • Tel: 44 (0) 1527 520 999
Fax: 44 (0) 1527 501 999 • Freephone: 0800 085 1678 (UK only)
E-mail: info@sti-europe.com • Web: www.sti-europe.com
CIRCUIT BOARD SET-UP
Nex
J
P5
J
P2
JP4
JP3
JP7
ALARM VOLUME SWITCH
TRIP DELAY SWITCH
ARMING SWITCH
(FACTORY DEFAULT SETTINGS)
(ON)
(ON)
(OFF)
(OFF)
(OFF)
ALARM CIRCUIT BOARD SET-UP
A
LARM
DURATION
S
WITCH
T
ERMINAL BLOCK
D
(
Inst. Sht. 7532, 7533, &7533AED, JAN2014
WARNINGS
WARRANTY INFORMATION
SPECIFICATIONS
All units are recommended for indoor use. Unit must be tested periodically to verify the life of battery. STI recommends you change the battery twice a year. Duracell
MN 1604 or equivalent recommended. Installer may need to purchase a simple audio-meter, typically available at your local electronics store, to measure the sound
in areas where the alarm is expected to be heard during normal noise environment. Results from this test may prove it beneficial to purchase an additional alarm.
When purchasing a remote unit (STI-6403) you will need to periodically test the connections to make sure audibles function at a sound level to alert staff. Maximum of
three STI-6403 may be used in parallel. All specifications and information shown are current as of publication and subject to change without notice.
· Three year guarantee against breakage of polycarbonate in normal use (one year on electro mechanical and electronic components).
· Electronic warranty form at www.sti-usa.com/wc14.
9 VDC Alkaline or 9V-24VDC wired
Class II UL Listed transformer
Horn Volume at 1 ft. 95 dB low / 105 dB high
Relay Output Form C Dry Contacts 0-30 VDC or VAC, 1 Amp
Stand by Current 10uA
Alarm Current 130mA at 95 dB / 200mA at 105 dB
Power Source
Polycarbonate Alarm Cover:
Dimensions 5.375” W x 5.375” H x 2 “ D (137mm x 137mm x 51mm)
Flammability: UL94 V-2
Wall Thickness: 0.12 in (3.05mm)
Alarm Electronics
backbox mounting tab slots. Use rubber
mallet if necessa
in closed position, against the wall. Mark and
drill (4) 1/4 in. diameter holes. Insert the (4)
19033 anchors.
3
inst
through the access hole at
view
wires are not pinched between the wall and cabinet.
Drive in the (4) screws. Cabinet is now secure.
I
Mark and drill 3/16 in.
B
FROM MAGNETIC
CONTACT SWITCH
backbox mounting tab slots. Use rubber
mallet if necessa
in closed position, against the wall. Mark and
drill (4) 1/4 in. diameter holes. Insert the (4)
19033 anchors.
3
inst
through the access hole at See
view Close and lock cabinet.
4
wires are not pinched between the wall and cabinet.
Drive in the (4) screws. Cabinet is now secure.
I
Mark and drill 3/16 in.
N
C
COM
N
O
GD
V
+
RS1
RS2
KEYSW
VIEW B
TERMINAL BLOCK WIRING CONNECTIONS
FORM C
DRY
CONTACTS
REMOTE
POWER
INPUT
9-24 VDC
KEY SWITCH
TERMINALS
MAGNETIC CONTACTTIC
REED SWITCH
JUMPER
VIEW B