Owner manual

- 3 -
Integral Sounder Tones (DIP Switch No. SW1-SW3)
TheAlertPointLitehassevendifferentselectablealarmtonesrangingfrom95to102dB.
Sounder Timer Options (DIP Switch No. SW5 & SW6)
FouralarmconditionsareavailableandcanbeselectedbychangingtheDIPswitchsettings.Theseare:
30seconds,3minutes,20minutesorcontinuous.
Ifanydurationotherthan“continuous”isused,thealarmwillsilenceaftertheselectedtimehaselapsed.
ThisalarmwillNOTbeabletobereactivateduntiltheunitisresetwiththeresetkey.
Key Switch – Reset (DIP Switch No. SW7)
Thisallowstheusergreatercontrolifmisusebecomesamajorfactor.
SW7 position - ON:TheAlertPointLitewillfullyresetafteractivationwhenusingtheresetkey.
SW7 position - OFF:EveniftheAlertPointLiteisresetafteractivationusingtheresetkey,allsounders
willcontinuetorununtiltheunitisresetusingthemasterkeyswitch.
DIP Switch Settings
Important: ChangestoanyDIPSwitchsettingswillonlytakeeffectaftertheAlertPointLitehasbeen
resetusingthemasterkeyswitch(turn“OFF”thenback“ON”).
FEATURES DIP SWITCH SETTING ACTION
Integral
Sounder Alarm
Tone
SW1 SW2 SW3 Tone Sound Pattern
OFF OFF OFF 1 800Hz - 970Hz (Sweep)
ON OFF OFF 2 800Hz - 970Hz (Sweep)
OFF ON OFF 3 988Hz / 250ms - 645Hz / 250ms (Alternating)
ON ON OFF 4 670Hz / 250ms - 845Hz / 370ms (Alternating)
OFF OFF ON 5 800Hz - 970Hz in 350ms (Sweep)
ON OFF ON 6 2400Hz - 2850Hz in 110ms (Sweep)
OFF ON ON 7 2400Hz - 2850Hz in 330ms (Sweep)
ON ON ON 8 Not implemented
SW5 SW6 Sounder Duration
OFF OFF Sounders run continuously (until manually reset)
ON OFF Sounders switch off automatically after 30 seconds
OFF ON Sounders switch off automatically after 3 minutes
ON ON Sounders switch off automatically after 20 minutes
Alert Point Lite returns to “standby” condition after resetting
with reset key.
Alert Point Lite latches in “alarm” condition until it is
manually reset using the master key switch.
The Alert Point Lite expects to be connected to another Alert
Point Lite, otherwise a warning beep is emitted.
No fault will be indicated if an Alert Point Lite is not connected
to another Alerrt Point Lite, it is not looking for a connection.
SW4 ON Not used
SW4 OFF Not used
Sounder
Duration Timer
Reset
Networking
the Alert Point
Lite
Factory setting
SW7 ON
SW7 OFF
SW8 ON
SW8 OFF
Programmable Features