Owner manual
Loss of Connection between Units
Any loss of connection within the network will indicated as a fault (double beep every 90
seconds) this will only be indicated on the unit expecting the input signal.
InDiagram3,the“NetworkIN”connectionislostonunit#2,Resultingin:
1: Unit #2–awarningdoublebeepwillbeemittedevery90seconds.
2: Unit #1–willnotbeabletotriggerunit#2intoalarmcondition,thesignalislosttothe“NetworkIN”
connectiononunit#2.
3: Unit #2–canstilltriggerunit#1intoalarmconditionastheconnectionremainsintactbetweenthe
“NetworkOUT”onunit#2andthe“NetworkIN”onunit#1.
4: Both units–willcontinuetoworkindependently.
5: Unit #2–willinstantlyreturntoits“standby”conditionwhentheconnectionisremade,without*
havingtoresettheunit.
*Note:tocheckthatthenetworkisfunctioningcorrectly,whileavoidinghavingtowait90secondsfor
verication,turntheunitOFFthenbackONusingthemasterkeyswitch(afaultwillemitadoublebeep
immediatelyonstartup).
- 6 -
Installing External sounders
1.Ensuretheunitisswitched“OFF.”
2.Inserttheexternalsoundersintothecorrectterminals.(seepage7)
Important:Pleasebesureallsoundershavetheirownpowersourceandarewiredin
accordancewiththeirowninstallationmanual.
Warning:IncorrectlyinstalledexternalsoundersmaycauseirreversibledamagetotheAlert
PointLite.
3.Turntheunit“ON”usingthemasterkeyswitch.
4.Test–Whentheoperatingelementispressed,theunitwillgointoalarmconditionandthe
externallyinstalledsoundersshouldnowactivate.
5.ResettheAlertPointLiteusingtheresetkey;allsoundersshouldnowsilence.
General Maintenance
9VDCbatteriesshouldbereplacedevery15 monthsorsooner.
Cleaningshouldbecarriedoutusingonlymild,diluteddetergents:concentratedsolutionsandthose
including(butnotlimitedto)alkalis,strongacids,ethers,amines,aromatichydrocarbonsandalcohols
cancauseconsiderableharmtothisproduct.
Network IN
Network COM
Network OUT
Network IN
Network COM
Network OUT
UNIT 1 UNIT 2
Diagram 3