Installation Instructions

ARCS Blue
Upgradable readers
Installation instructions
ARCS Blue
Lecteurs évolutifs
Notice d’installation
ARCS Blue
Lectores escalables
Procedimiento de instalación
conforme con
NOM-024 -SCFI-2013
STid reserves the right to make change without notice, for the purpose of product improvement.
Screw terminal output product references
Cable output product references
J6: Antenna connector
J7: Keypad connector
J9: Biometric connector
J14: Display connector
J15: Output cable
J15
Type
Wiegand
Clock & Data
RS485
1
Dark blue
SW2
2
Pink
SW1
3
Orange
Led 2
4
White
Buzzer
5
Yellow
Clock
Clock
NC
6
Red
+Vcc (+7 Vdc to +28 Vdc)
7
Blue
D1
Data
NC
8
Grey
D0
Code
NC
9
Green
Led 1
10
White Brown
NC
NC
L+
11
White purple
NC
NC
L-
12
Brown
0 Vdc
Power supply characteristics
Use an AC/DC power supply type LPS, Limited Power Source (as per IEC/UL/EN 60950-1 Ed2) or type ES1, PS1 (according to IEC/UL/EN 62368-1) for the main supply.
Main power supply: Range: +7 Vdc to +28 Vdc Typical: 12 Vdc
Max. consumption at 12 Vdc:
ARCS-A/BT1:
150 mA
ARCS-B/BT1:
180 mA
ARCS-C/BT1:
220 mA
ARCS-D/BT1:
300 mA
ARCS-E/BT1:
330 mA
ARCS-F/BT1:
370 mA
ARCS-I/BT2:
180 mA
ARCS-IM/BT2:
190 mA
ARCS-J/BT2:
210 mA
ARCS-JM/BT2:
220 mA
ARCS-K/BT2:
250 mA
ARCS-KM/BT2:
260 mA
ARCS-AQ/BT1:
260 mA
ARCS-BQ/BT1:
300 mA
ARCS-CQ/BT1:
340 mA
Characteristics
Communication: RS485 (L+ & L-) / TTL (Wiegand / Clock and Data)
Connection: Removable connectors 1x10 pins and 1x2 pins, thread 0.19685 inch OR cable.
Protection: IP65 classified reader
Static relay: ASSR-1218-003E: 60 V output withstand voltage / 0.2A current rating / low on-resistance 1 Ω typical for AC/DC
Recommended cables
Screw terminal output: RS485: Use a multi-conductor shielded twisted pair cable. Max. length: 3281 ft at 9600 baud
Wiegand / Clock & Data: Use an untwisted shielded multi-conductor. For data:
2 wires AWG24 98 ft max / 4 wires AWG24 197 ft max / 6 wires AWG24 328 ft max
2 wires AWG20 164 ft max / 4 wires AWG20 328 ft max
Cable output (cable supplied): TRANXALARM - 14x0.22mm
2
- lg 3.05m
Buzzer / LED
The operating mode for the Buzzer and LED 1 and 2 can be programmed by a configuration card (SCB / OCB) or controlled by the remote system with a 0 Vdc
respectively on the
Led 1
”, “
Led 2
” and “
Buzzer
” inputs of the reader’s connector or controlled by the communication protocol of the reader (SSCP
®
/ OSDP
TM
).
Anti-tearing
Tearing is detected by an accelerometer. When the reader is wrenched, the switch output (connector J2) provides an O/C contact to indicate the tearing of reader.
for R/S 31/x1: the wrenching signal will be emitted on the “Data/Data1” line. This function is configurable via a configuration card.
for R/S 33/x3 and OSDP
TM
: the reader will perform the operations configured with the configuration card.
for W33/x3: the reader will perform the operations configured with the SSCP
®
protocol.
Caution: switch on the reader when it is in its final position to initialize the accelerometer in the correct position.
ARCS-X/BT1
X:
A: Standard
B: Keypad
C: Touch screen
D: Standard + Biometrics
E: Keypad + Biometrics
F: Touch screen + Biometrics
AQ: Standard + QR Code
BQ: Keypad + QR Code
CQ: Touch Screen + QR Code
ARCS-X/BT2
X:
I / IM: Standard + 125 kHz module
J / JM: Keypad + 125 kHz module
K/ KM: Touch screen + 125 kHz module
ARCS-XC/BT1
X:
A: Standard
B: Keypad
C: Touch screen
D: Standard + Biometrics
E: Keypad + Biometrics
F: Touch screen + Biometrics
Connector
Type
J4
Wiegand
Clock & Data
RS485
1
0 Vdc
2
+Vcc (+7 Vdc to +28 Vdc)
3
D0
Code
NC
4
D1
Data
NC
5
Clock
Clock
NC
6
NC
NC
L+
7
NC
NC
L-
8
Led 1
9
Led 2
10
Buzzer
J6: Antenna connector
J7: Keypad connector
J9: Biometric connector
J14: Display connector
J2: O/C contact
US
FR
ES