Installation Instructions

ARCS Blue
Upgradable readers
Installation instructions
ARCS Blue
Lecteurs évolutifs
Notice d’installation
ARCS Blue
Lectores escalables
Procedimiento de instalación
conforme con
NOM-024 -SCFI-2013
STid reserves the right to make change without notice, for the purpose of product improvement.
Relay
Read-only reader: automatic tamper management (except touch screen) or activated on the reading of a valid identifier
Touch screen read-only reader: if the bell is activated, contact J2 is used to connect the external ring (max. 200 mA at 28 Vdc).
Read/Write & OSDP
TM
readers: the relay is controlled by the SSCP
®
/OSDP
TM
protocol commands.
UHF default configuration settings
Reader powered off. The defaults reader settings can be stored in internal memory accessible by UHF RFID technology. They will be taken into account when the
reader is powered on.
Read-only reader configuration
R and S readers are configurable with SCB RFID / virtual configuration card.
OSDP
TM
readers are configurable with OCB RFID / virtual configuration card or with FileTransfer command.
If the SCB/OCB is compatible with the reader’s firmware, the LED lights green and the buzzer beeps five times.
If the SCB/OCB is not compatible with the reader’s firmware, the LED lights red and the buzzer is activated for 1 s.
If the SCB/OCB key is different from the reader’s key: no reaction.
Caution: set your reader with your own company key.
Powering-up the readers
On power-up, the reader enters an initialization phase:
1. Activation of the white LED and buzzer for 100 ms.
For read-only & OSDP
TM
readers:
2. Activation of the LED, according to the color code: Red = +10, Orange = +5, Green = +1, indicating the firmware version.
3. For serial R/S reader only: the orange LED flashes 20 times: waiting for an update.
4. For Bluetooth
®
reader only: Activation of white fixed LED during Bluetooth® initialization.
5. Activation of the default LED (read-only: flashes blue, OSDP
TM
: off; if no customer specific configuration).
6. For the ARC screen with an activated keypad, the default mode is: display the picture on standby and activate the keyboard by pressing the screen.
Precautions for the biometric sensor and keypad
For optimal operation, the biometric sensor must be free of all traces of water. Outdoors it is recommended to install the reader under cover.
The keypad is sensitive. Take off your gloves to enter your code.
Caution for Bluetooth® reader
Caution: at the reader Bluetooth® (BT1/BT2) powering, make sure that nothing is in an area of at least 10 cm / 3.94 in. around the reader (ex. No hand in front of the
reader…).
Precautions for installation
The supply voltage at the reader’s connector should be between +7 Vdc and +28 Vdc.
As far as possible, keep the reader away from computer or power source cables. They can generate electrical interference, depending on their radiation level and
the proximity of the reader.
Recommended distance between two readers: parallel plane: 15.8 in same plane: 15.8 in perpendicular plane: 11.8 in.
Recommended distance between two Bluetooth
®
readers: 2 meters / 78.74 inch either plan.
Place the reader at a height of less than 2 meters / 78.74 inch (standard UL/IEC 62368).
If the reader is fixed on a metal surface, it is possible to have a reduction in the reading distance.
Use a ferrite (two-way) for the cable (power supply and data).
Example: reference 74271222 WURTH ELEKTRONIK
.
For ARCS screw terminal output reader, connect the 2.2 µF capa (provided) between +12V and GND directly to the output of the connector (no polarization).
By design, the reader can be installed indoors and outdoors.
BEFORE powering on, connect the wires or the connector of the reader. Before disconnecting the wires or the connector of the reader, power off.
Operating temperature:
Temperature
-22 °F to 158 °F
-30°C to +70°C
-22 °F to 140 °F
-30°C to +60°C
-4 °F to 158 °F
-20°C to +70°C
-4 °F to 140 °F
-20°C to +60°C
14 °F to 122 °F
-10°C to +50°C
Readers
A, B, IM, JM
AQ, BQ
C, I, J, K, KM
CQ
D, E, F
TTL pull-ups
For data signals, 10k pull-up resistors are connected internally to V
in
(power supply voltage) for optimal wiring distances.
RS485 communication
Bus architecture (RS485)
RT: 120 Ω end-of-line resistor supplied.
From version 07 of the electronic board, the readers are fitted directly with pull-up / pull-down resistors on the electronic board.
Earlier versions require the wiring of resistors R1 and R2 (1.5 kΩ resistors supplied) to use the extended features of the RS485 Bus: FAIL-SAFE (see RS485-AN-960).
US
FR
ES
Available Baud rate
9600, 19200, 38400, 57600, 115200 bauds
Factory Baud rate
ARC R & S: 9600; ARC W: 38400 (SSCP
®
), 9600 (OSDP
TM
)
Mode
Asynchronous
Number of bits
8
Transfer mode
LSB first
Stop bit
1
RS485
Default broadcast address 00h
More details about
reader communication
are available in the
protocol specification