Submittal Sheet

17 West St., W. Hatfield, MA 01088 | 800.582.8423 | 413.247.3380 | fax 413.247.3369 | info
@
stiebel-eltron-usa.com | www.stiebel-eltron-usa.com
rev. 5.2021 | Due to our continuous process of engineering and technological advancement, specifications may change without notice.
DHC-E Trend & DHC-E Plus Electric Tankless Water Heater
Applications
Engineer/Architect: __________________________________________________________________________________________________________________________________________ Date: _________________________________________________________________________________
Job Name/Customer: ______________________________________________________________________________________________________________________________________ Phone: _____________________________________________________________________________
Location:____________________________________________________________________________________________________________________________________________________________________ Date Required: _________________________________________________________
Contractor: ______________________________________________________________________________________________________________________________________________________________ Phone: _____________________________________________________________________________
Water Heater Specifications
Item No. Quantity kW Voltage Amperage
Model # DHC-E Trend/Plus
_____________________________________
________________________________ ________________________________ ________________________________ ________________________________ ________________________________
Commercial › Industrial › Institutional Residential
› Office Buildings › Gas Stations › Bathroom Sinks
› Stores › Schools › Kitchen Sinks
› Malls › Hotels / Motels › Laundry Areas
› Warehouses › Commercial Condominiums › Cabins / Cottages
› Restaurants › Manufacturing Facilities › Low Flow Showers
Specications
SUBMITTAL SHEET
Simply the Best
Model DHC-E 3/3.5-1 Trend DHC-E 4/6-2 Trend DHC-E 8/10-2 Trend
DHC-E 8/10-2 Plus
DHC-E 12/15-2 Trend
DHC-E 12/15-2 Plus
Item no. 200057 200061 200058 (Trend)
202145 (Plus)
200059 (Trend)
200056 (Plus)
Phase
- 50/60 Hz 1
Voltage 120 V 240 V 208 V 240 V 208 V 240 V 208 V
Wattage
1
, jumper position
1 [low] / 2 [high]
3 kW / 3.5 kW 3.8 kW / 6 kW 2.9 kW / 4.5 kW 7.2 kW / 9.6 kW 5.4 kW / 7.2 kW 12 kW / 14.4 kW 9 kW / 10.8 kW
Amperage, jumper position
1 [low] / 2 [high]
25 A / 29.2 A 15.8 A / 25 A 13.9 A / 21.7 A 30 A / 40 A 26 A / 34.6 A 50 A / 60 A 43.3 A / 52 A
Min. recommended circuit breaker size
2
,
jumper position 1 [low] / 2 [high]
25 A / 30 A 20 A / 25 A 15 A / 25 A 30 A / 40 A 30 A / 35 A 50 A / 60 A 50 A / 60 A
Min. recommended AWG wire size
3
,
jumper position 1 [low] / 2 [high]
10/2 / 10/2 12/2 / 10/2 14/2 / 10/2 10/2 / 8/2 10/2 / 8/2 8/2 / 6/2 8/2 / 6/2
Minimum water ow
to activate unit
0.264 gpm (1.0 l/min)
Weight 5.5
lb (2.5 kg)
Dimensions
Height 14
1
/
8
 (360 mm) x Width 8 (202 mm) x Depth 4
5
/
16
 (109 mm)
Nominal water volume 0.07
gal (0.277 l)
Max. permissible inlet temperature
149 °F (65 °C)
Maximum permissible pressure 145 psi (10 bar)
Water connections
3
½ NPT
DHC-E 3/3.5-1 Trend and 4/6-2 Trend ship with pressure compensating fl ow-reducer/aerators that must be installed.
1 Factory default setting is jumper position 2 [high]
2 Overcurrent protection sized at 100% of load. Tankless water heaters are considered a non-continuous load. Use only GFCI Class A circuit breakers.
3 Copper conductors with a temperature rating of 75 °C or greater must be used. Conductors should be sized to maintain a voltage drop of less than 3%
under load.
These are our recommendations. Check local codes for compliance if necessary.
Tested and certified by WQA
against NSF/ANSI 372 for lead
free compliance.
Certified to ANSI/UL Std. 499
Conforms to CAN/CSA Std. C22.2 No. 64
Technical Data

Summary of content (3 pages)