OPERATING AND INSTALLATION OPERACIÓN E INSTALACIÓN UTILISATION ET INSTALLATION DHW HEAT PUMP WATER HEATER CALENTADOR DE AGUA CON BOMBA ELÉCTRICA DE CALOR CHAUFFE-EAU THERMODYNAMIQUE » ACCELERA® 300 STIEBEL ELTRON Inc. 17 West Street | West Hatfield MA 01088 Tel. 413-247-3380 | Fax 413-247-3369 Email info@stiebel-eltron-usa.com www.stiebel-eltron-usa.com A 280011-36221-8653 The Accelera® 300 Heat Pump Water Heater is tested and certified by WQA against NSF/ANSI 372 for lead free compliance.
GENERAL INFORMATION QUICK START-UP GUIDE Please read Read these instructions carefully and retain them for future reference. If the water heater is passed on to a third party please hand these instructions to the new user. This manual includes important information regarding the safe and efficient handling of the water heater. Keep this manual with the water heater at all times. Work must only be carried out by a licensed installer who has read and understands these instructions.
1 8 3 5 6 C M 9 10 7 Cold water H Hot water 2 15 4 12 11 13 14 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Vacuum breaker Hot water connection (Union adaptor to 3/4") Mixing valve (optional, supplied by installer) Connection for T&P valve ¾" T&P valve ¾", 0.69 MPa @99 °C (100 psi @210 °F) (supplied with unit) 0.
CONTENTS | OPERATION GENERAL INFORMATION ____________________________________________2 QUICK START-UP GUIDE ____________________________________________2 OPERATION __________________________________________________________5 1. Overview ____________________________________________________5 2. 2.1. General information ________________________________________5 Key to symbols ___________________________________________________ 5 3. 3.1. 3.2. 3.3. 3.4. 3.5. 3.6.
OPERATION OVERVIEW Back of the water heater Overview ENGLISH 1. Front of the water heater 1 9 10 7 11 2 3 26_03_01_1337 8 6 4 1 2 3 4 5 6 7 8 4 4 26_03_01_1338 5 Water heater cover Opening for PT valve Condensate drain Leveling feet Cold water inlet Hot water outlet Air entry Condensate spillover 9 Air discharge 10 Entry for the power cable 11 Information labels, serial no.: An 80 gallon water tank is part of the water heater.
OPERATION GENERAL INFORMATION 2. 2.1.4 Symbols in this documentation General information The chapter Operation is intended for users and licensed installers. Read the text next to this symbol carefully. The chapter Installation is intended for licensed installers only. 2.1 » Passages with the symbol "»" indicate that you have to do something. The action you need to take is described step by step. - Passages with this symbol "–" indicate lists. Key to symbols 2.1.
OPERATION GENERAL INFORMATION This label shows you the position where the water heater drain is located. 1 5 CAUTION ! DANGER HOT 284760-34684 280302-34812 6 lief valve 280557-35826 DHW outlet 280304-34684 280304-346845 280305-35826 mus e e o e c ear y mar e socket. The valve drain outlet pipe must not be sealed or blocked, and the valve easy gear is to be operated at least once every six month.
OPERATION GENERAL INFORMATION 9 Type plate WW Austritt 280304-34684 Single phase 220-240 V, 50/60 Hz 15 amp. Limits for heat pump operation: Maximum allowable ratings Protection class: Heat pump: PN (Air 42° / Water 60°): IN (Air 42° / Water 60°): Type of Refrigerant: Refrigerant charge: Max. operating pressure: Lock rotor current: MCA: Rated load compressor: Motor fan: 6 °C / +42 °C 2200 W, 9.17 A IP 24 xxxx / xxxxxx 280304-34684 Nmax 5 Information label "Relief valve" Warning 0.5 kW 2.
3. Safety This water heater must not be operated at ambient temperatures in excess of 42 °C (107 °F) or below 6 °C (43 °F). If outside air is directly drawn in ensure, that the water heater is isolated from its power supply when the air temperature falls below 6 °C (43 °F). This chapter provides an overview of all important actions required for a safe and trouble-free operation. 3.1 General safety instructions Operate the water heater only when fully installed and with all safety equipment in place.
OPERATION WATER HEATER DESCRIPTION 4. Water heater description This water heater is an automatic hot water generator with approx. 303 l (80 gallon) capacity. The hot water temperature is factory set to 60 °C (140 °F). After opening a hot water faucet, the hot water is pushed out of the water heater by the incoming cold water. This water heater works like an air conditioner but does not need to be vented. The water heater extracts heat from the ambient air to heat the water.
7.2 ... the safety valve of the cold water supply line is dripping This unit can operate up to 0.48 MPa (70 psi) of inlet pressure. Expansion water drips from the safety valve during heat-up. This is completely normal. Notify your local licensed installer if water still drips after heat-up has been completed. 7.3 ... the condensate drain drips This is quite normal and always happens when the surface temperature of the evaporator is lower than the dew point temperature of the ambient air. 1 1 6.
OPERATION WATER HEATER DESCRIPTION WARNING Injury Moving parts represent a risk of injury. » Before opening the water heater, ensure that the fan has come to a complete standstill. 8.
INSTALLATION INSTALLATION 10. Installation 10 CAUTION Injury Incorrect installation can result in severe injuries and material losses. Prior to installation ensure you have adequate space for the work to be carried out. Handle components with sharp edges carefully. The sheet steel casing of the water heater is not designed to withstand heavy forces. Handle and install the water heater with care. 10.
INSTALLATION INSTALLATION (15,75") 10.2 Shipping inspection » Upon receipt, check your delivery for completeness and possible transport damage. If transport damage is visible, proceed as follows: - Do not accept the delivery or only with reservations. - Note down the extent of the damage on the shipping documents or on the delivery note of the carrier. - Initiate a complaint. Immediately give notice of any damage. Give notice of all damage as soon as it has been identified.
DANGER Injury from overturning Secure the water heater against overturning by getting a second person to support the water heater. » Push a wooden support underneath the lower part of the packaging. » Break out the free semi-shell of the lower section of the packaging. » Push two polystyrene® installation aids with the step-shaped corner underneath the water heater. The water heater is subsequently set and tilted onto this profile.
INSTALLATION INSTALLATION 10.6.1 Condensate drain 6 3 5 1 1 2 3 4 5 6 2 26_03_01_1127 < 889 (35") 26_03_01_1388 » Tilt the water heater that has been set down on the polystyrene® installation aids. » Remove the remaining floor semi-shell. » In the tilted state of the water heater, wind out the second and third leveling foot, but not by more than 30 mm (1.1"). » In both cases, tighten the locking nut against the bottom cover. » Position the water heater on the three leveling feet.
10.7 Water connection The water connection must be carried out by a qualified licensed plumber. The cold water connection must comply with DIN 1988 [or state and local codes] » Prior to installing the water heater, flush the line thoroughly. 8 5 Hot water C M 6 H 12 2 15 Install a 0.48 MPa (70 psi) pressure reducing valve on the cold water inlet. Accurately maintain the order of fittings on the cold water side (see diagram 10.7). 10.7.
INSTALLATION INSTALLATION 1 2 CAUTION : Risk of electric shock Use copper conductors only 16 3 4 Risk of electric shock Ris Us copper conductors only Use 15 5 6 14 Air flow 7 → 8 Air flow → 13 9 11 12 11 12 13 14 15 16 Capacitor Cable entry into the water heater casing Strain relief (cable clamp) Mains terminal Frost monitor Heat pump control thermostat Fan motor Heat pump terminal Thermostat, booster heater High limit safety cut-out, booster heater, manual reset (see 14.1.
INSTALLATION INITIAL START-UP ENGLISH 12.2 Knob settings 11. Initial start-up 11.1 Initial start-up Only approved, licensed installers may perform the initial start-up of this water heater, and instruct the user in its operation. » Fill and vent the water heater. For this, open the cold water supply and one hot water tap. » Thoroughly flush the water heater. » Check the safety valves. Inform the user that water may drip from the safety valve while water is being heated up.
INSTALLATION MAINTENANCE AND CLEANING The safety high pressure limiter shuts down the compressor if the pressure inside the refrigerant circuit exceeds the permissible maximum value. The safety high pressure limiter may also trip if the water heater is operated above its permissible limit, i.e. above an air temperature of 42 °C (107 °F). (See above) The safety pressure limiter also trips if the heat pump thermostat fails.
INSTALLATION MAINTENANCE AND CLEANING 15.4 Descaling ENGLISH » Close the shut-off valve in the cold water supply to the tank. » Draw water from the tank to relieve the pressure inside the water heater. 1 3 1 2 3 26_03_01_1025 CAUTION : Risk of electric shock Use copper conductors only 2 Low pressure fill port High pressure fill port Booster heater flange » Unscrew the booster heater flange and remove element.
INSTALLATION SPECIFICATION 16. Specification 16.1 Connection and dimensions g01 b01 g02 c13 1840 (72.44") c01 D0000018497 185 (7.28") 660 (25.98") d43 1265 (49.8") d45 22-32 (0.87"-1.26") 1695 (66.
INSTALLATION SPECIFICATION L1 E1 F1 F2 F3 M1 M2 N0 N1 N2 L2 26_03_01_0882 1,65 kW ENGLISH 16.2 Wiring diagram G Booster heater High limit safety cut-out, booster heater Compressor motor protection (Klixon) Safety pressure limiter (high pressure) Compressor Fan Heat pump control thermostat Thermostat - booster heater Frost monitor WWW.STIEBEL-ELTRON-USA.
INSTALLATION SPECIFICATION 16.3 Refrigerant diagram 1 !P TKW TWW 6 PC 5 3c 2 P0 3a TC 4 1 2 3a 3b 3c 4 5 6 PC P0 >P TC Air flow VLuft VAir 26_03_01_0764 3b Tank w/ heat condenser, jacket & temperature sensors Filter dryer Expansion valve Capillary tube Capillary bulb Fan & evaporator Compressor Check valve Service valve high pressure Service valve low pressure High pressure safety switch Thermostatic expansion valve 24 | ACCELERA® 300 HEAT PUMP WATER HEATER WWW.STIEBEL-ELTRON-USA.
INSTALLATION SPECIFICATION Model Heat pump water heater Type Accelera 300 Part number 222423 Version With passive defrosting and booster heater Operating details Lower application limit for heat pump operation (air temperature) °C (°F) 6 (42.8) Upper application limit for heat pump operation (air temperature) °C (°F) 42 (107.6) Hot water temperature, heat pump °C (°F) 60 (140) Hot water temperature, booster heater °C (°F) 60 (140) m3/h (CFMs) 550 (324) l (Gal) 303 (80.
INSTALLATION SPECIFICATION Model Heat pump water heater Electrical details Power connection, voltage / frequency L1,L2,G / 208-240 V / 60/50 Hz Protection Maximum power consumption (Tamb = 42 °C (108 °F), Twater = 60 °C (140 °F), 240 V) IP 24 kW 2.2 Required circuit breaker size A 15A double pole breaker Rated power consumption, heat pump A 2.
WARRANTY ENVIRONMENT AND RECYCLING Stiebel eltron warrants to the original owner that the Accelera® 300 heat pump water heater will be free from defects in workmanship and materials for a period of ten (10) years from the date of purchase. Should the part(s) prove to be defective under normal use during this period, Stiebel Eltron, Inc. will be responsible for replacement of the defective part(s) only. Stiebel Eltron, Inc.
4 Subject to errors and technical changes. Stand 8643 A 280011-36705-8737 North, Central, and South America United States of America STIEBEL ELTRON, Inc. 17 West Street | West Hatfield, MA 01088 Tel. 0413 247-3380 | Fax 0413 247-3369 Email info@stiebel-eltron-usa.com Web www.stiebel-eltron-usa.