Use and Care Manual

WWW.STIEBEL-ELTRON-USA.COM SUNWARMTH
CIR INFRARED HEATER| 21
ENGLISH
INSTALLATION
SPARE PARTS
11.4 Specification table
Model CIR 150-1 I CIR 150-1 O CIR 200-2 O CIR 400-2 O
Item No. 234047 234048 234049 234050
Usage indoor only indoor/outdoor indoor/outdoor indoor/outdoor
Testing standard ANSI/UL 1278 ANSI/UL 1278 ANSI/UL 2021 ANSI/UL 2021
Voltage, 60Hz 115–120 V 115–120 V 230–240 V 230–240 V
Wattage 1.5 kW 1.5 kW 2.0 kW 4.0 kW
Amperage 12.5 A 12.5 A 8.3 A 2 x 8.3 A
Required number and size of
circuit breakers
N/A
N/A
15 A
2 x 15 A
Required wire size (copper) 14 AWG 14 AWG 12 AWG 12 AWG
Lamp temperature 2420 °F, ±360 °F
1325 °C, ±200 °C
2420 °F, ±360 °F
1325 °C, ±200 °C
2420 °F, ±360 °F
1325 °C, ±200 °C
2420 °F, ±360 °F
1325 °C, ±200 °C
Lamp life (normal conditions) 5000 hours 5000 hours 5000 hours 5000 hours
Lamp color temperature 1600 K, ±200 K 1600 K, ±200 K 1600 K, ±200 K 1600 K, ±200 K
Height 5
11
/16˝ / 145 mm 5
11
/16˝ / 145 mm 5
11
/16˝ / 145 mm 5
11
/16˝ / 145 mm
Width 15
9
/16˝ / 395 mm 18
9
/16˝ / 471 mm 18
9
/16˝ / 471 mm 38 ½˝ / 978 mm
Depth 4
7
/16˝ / 112 mm 4 ¼˝ / 108 mm 4 ¼˝ / 108 mm 4
7
/16˝ / 112 mm
Weight 4.85 lb / 2.2 kg 5.5 lb / 2.5 kg 5.5 lb / 2.5 kg 8.8 lb / 4.0 kg
IP-Rating IP20 IP24 IP24 IP24
Protection class I I I I
Color alpine white alpine white alpine white alpine white
12. Spare Parts
Model Protective Grill Heat Lamp
CIR 150-1 I BHSG LGHS1520 120V
CIR 150-1 O BHSG LGHS1524 120V
CIR 200-2 O BHSG LGHS2024 240V
CIR 400-2 O BHSG (2) LGHS2024 240V
13. What to do if ...
... the appliance does not heat up:
» For 120 V models, ensure that the unit is plugged into a properly
grounded 120 V wall outlet and that the timer switch is on.
» For 240 V models, ensure that the timer switch is on and that
there is adequate power available at the circuit breaker and that
the breaker hasn’t tripped. Check for faulty breaker(s).
... you notice a smell:
» For a short time after initial installation or after a long period
of inactivity, the unit may produce a smell. This is normal and
will not last long once regular operation resumes.
If you cannot remedy the fault, contact your contractor. To facilitate
and speed up your enquiry, please provide the number on the type