Operating Instructions and Installation Instructions
8 | DHB-E AU www.stiebel-eltron.com
INSTALLATION
Installation
160
30
1
26�02�02�0824�
1 Installation aid
Prepare the power cable.
Preparing the water connection
!
Material losses
Carry out all water connection and installation work in
accordance with regulations.
D0000041720
Remove the caps from the tees.
Fit the plugs and the extensions with gaskets.
D0000041721
Fit the strainer in the tee for the cold water inlet.
!
Damage to the appliance and environment
The strainer must be fitted for the appliance to function.
When replacing the appliance, check that the strain-
er is present.
D0000041722
12
1 Flow limiter
2 Plastic profile washer
Fit the flow limiter or plastic profile washer.
Note
Install the flow limiter.
With low water pressure.The pressure drop can be
reduced by replacing the flow limiter with the plastic
profile washer provided.
Installing the appliance
26�02�02�1336
For easy installation, push the cable grommet of the upper
electrical connection into the back panel from behind.
Remove the transport plugs from the water connections.
Remove the fixing toggle from the upper part of the back
panel.
Route the power cable through the cable grommet from be-
hind, until the power cable rests against the cable sheath.
Align the power cable.
If the cross-section is >6mm², enlarge the hole in the cable
grommet.
Press the appliance over the threaded stud of the wall
mounting bracket. When doing so, push through the soft
seal in the back panel of the appliance. If necessary, use a
screwdriver.
Push the fixing toggle on to the threaded stud of the wall
mounting bracket.
Push the back panel of the appliance on to the wall. Turn the
fixing toggle 90° clockwise to lock the appliance in place.