INSTALLATION
Maintenance
14. Maintenance
WARNING Electrocution
Before any work on the appliance, disconnect all poles
from the power supply.
Draining the appliance
You can drain the appliance for maintenance work.
CAUTION Scalding
Hot water may escape when draining the appliance.
Close the shut-off valve in the cold water inlet line.
Open all draw-off valves.
Undo the water connections on the appliance.
Store the dismantled appliance in a room free from the risk
of frost, as water residues remaining inside the appliance can
freeze and cause damage.
Cleaning the strainer
A strainer is located in the tee from the cold water inlet pipe. In
case of contamination, you can remove this strainer and clean it.
D0000041722
1 32
1 Flow limiter or
2 Plastic profile washer
3 Strainer
Remove the flow limiter or plastic profile washer (selected
during installation).
Remove the strainer and clean the components.
Fit the strainer and the plastic profile washer or flow limiter.
15. Specification
15.1 Dimensions and connections
473
478
100
414
44
105≤ 20225
140
30
35
35
114
368
b02
c01c06
493
D0000043287
b02 Entry electrical cables I
c01 Cold water inlet Male thread G 1/2 A
c06 DHW outlet Male thread G 1/2 A
Alternative connection options
165
50
44
30
35
72
325
338
47
b03
b02
b04
b04
b04
b04
b04
D0000043288
b02 Entry electrical cables I
b03 Entry electrical cables II
b04 Entry electrical cables III