Specification

Simply the Best
DHX Trend & Plus Technical Specications
Simply the Best
17 West St., W. Hatfield, MA 01088 | 800.582.8423 | 413.247.3380 | fax 413.247.3369 | info
@
stiebel-eltron-usa.com | www.stiebel-eltron-usa.com
rev. 12.2020 | Due to our continuous process of engineering and technological advancement, specifications may change without notice.
Model DHX 3.5-1
Trend
DHX 6-2
Trend
DHX 8-2
Trend
DHX 10-2
Trend
DHX 12-2 Trend
DHX 12-2 Plus
DHX 12-2 Trend
DHX 12-2 Plus
Item no. 200067 203795 200068 200069 200070 (Trend)
200066 (Plus)
200071 (Trend)
202151 (Plus)
Phase
- 50/60 Hz 1
Voltage 120
V 240 V 208 V 240 V 208 V 240 V 208 V 240 V 208 V 240 V 208 V
Wattage 3.5 kW 6 kW 4.5 kW 7.2 kW 5.4 kW 9.6 kW 7.2 kW 12 kW 9 kW 14.4 kW 10.8 kW
Amperage 29.2 A 25 A 21.7 A 30 A 26 A 40 A 34.6 A 50 A 43.3 A 60 A 52 A
Min. recommended
circuit breaker size
1
30 A 25 A 25 A 30 A 30 A 40 A 35 A 50 A 50 A 60 A 60 A
Min. recommended
wire size
2
10/2 AWG 10/2 AWG 10/2 AWG 8/2 AWG 8/2 AWG 6/2 AWG
Minimum water flow
to activate unit
0.264 gpm (1.0 l/min)
Weight 5.5
lb (2.5 kg)
Dimensions
Height 14
1
/
8
� (360 mm) x Width 8� (202 mm) x Depth 4
5
/
16
� (109 mm)
Nominal water volume 0.07
gal (0.277 l)
Max. permissible inlet
temperature
149 °F (65 °C)
Maximum permissible
pressure
145 psi (10 bar)
Water connections
3
½� NPT
DHX 3.5-1 and 6-2 Trend ship with pressure compensating fl ow-reducer/aerators that must be installed.
1 Overcurrent protection sized at 100% of load. Tankless water heaters are considered a non-continuous load. Use only GFCI Class A
circuit breakers.
2 Copper conductors with a temperature rating of 75 °C or greater must be used. Conductors should be sized to maintain a voltage
drop of less than 3% under load.
These are our recommendations. Check local codes for compliance if necessary.
Tested and certified by WQA
against NSF/ANSI 372 for lead
free compliance.
Certified to ANSI/UL Std. 499
Conforms to CAN/CSA Std. C22.2 No. 64
Technical Data
Scroll for temp. rise charts.

Summary of content (2 pages)