Mount the applicance at least 48˝ above the fl oor.
8. Preparation
The Galaxy hand dryer must have its own independent circuit using 3 wire cable
of the appropriate size protected by a correctly rated double-pole circuit breaker.
The Galaxy 1 unit for 110-120V requires a 20 A circuit breaker and AWG 12 copper
wire. The Galaxy 2 unit for 220-240V or 208V requires a 15 A circuit breaker and
AWG 12 copper wire.
Transfer the four mounting points to the wall and trace the electrical wiring
entry point using the enclosed drilling template.
Feed the electrical wiring through the entry point traced with the template.
Remove the two screws at the air outlet grill and the screw on the locking slide.