Specification

17 West St., W. Hatfield, MA 01088 | 800.582.8423 | 413.247.3380 | fax 413.247.3369 | info
@
stiebel-eltron-usa.com | www.stiebel-eltron-usa.com
rev. 2017.11 | Due to our continuous process of engineering and technological advancement, specifications may change without notice.
Tested and certified by WQA
against NSF/ANSI 372
for lead free compliance.
Model MegaBoost
Part number 524201
Weight 5.9 lbs / 2.7 kg
Min. flow to activate 0.264 gpm / 1.0 l/min
Max. inlet water temp. 131°F / 55°C.
Operating Pressure Min. 30 psi, Max. 150 psi
Cover White ABS
Simply the Best
MegaBoost Tankless Electric Water Heater Booster
Features
Model Phase Voltage kW Amps Circuit
Breaker
Minimum
Wire Size
MegaBoost single 240 V 9.6 40 40 8 AWG
single 208 V 7.2 35 35 8 AWG
Significantly increases mixed water volume
Greatly decreases tank recovery times
High limit switch with manual reset
Easy installation ½" NPT connections
Exclusive design prevents dry firing
No additional T&P relief valve needed
(Check local code)
7 year leakage/3 year parts warranty
› Booster for electric or gas tank water heater
Model
Copper sheathed heating element housed in
copper cylinder
On-demand, continuous hot water
99% efficiency
Flow sensor & electronic control activated
for silent operation
Conveniently mounts on wall
Engineered and manufactured in Germany
84335
Certified to ANSI/UL Std. 499
Conforms to CAN/CSA
Std. C22.2 No. 64
ENGINEERING SPECIFICATION SHEET
Electrical cable entry
cold water inlet
½" NPT
1½"
(38 mm)
14 3/16" (360 mm)
7" (200 mm)
3 15/16"
(100 mm)
4"(110 mm)
10¾" (273 mm)
2 15/16"
(75 mm)
5/16" (8 mm)
hot water outlet
½" NPT
DHC-E 8/10
2/GRD ~ 208 / 240 V
1/N/PE ~ 220 / 230 / 240 V
85_02_03_0001

Summary of content (2 pages)