OPERATION AND INSTALLATION HIGH PERFORMANCE FLAT-PLATE COLLECTOR » SOL 27 PREMIUM S » SOL 27 PREMIUM W
Simply the Best INSTALLATION INSTRUCTIONS SOL 27 PREMIUM S & W COLLECTORS - 230016 & 230017 Table of Contents 1 Safety instructions 2 Collector basics 3 Assembly instructions 3.1 Important information responsibility of the installer. Failure to comply with the installation and operating instructions or improper use voids the warranty. Save these instructions for future reference. Installers should leave these instructions with the consumer.
Simply the Best INSTALLATION INSTRUCTIONS SOL 27 PREMIUM S & W COLLECTORS - 230016 & 230017 The air-side inlet pressure should be ser to 5-7 psi less than the system start-up (cold) pressure; check it when the system has not been filled or when the wet side of the expansion tank is open to the atmosphere. WARNING: SET TING T HE MAXIMUM TANK T EMPER AT URE HIGHER T HAN 140 F AT THE CONTROL UNIT IS PERMISSABLE ONLY WITH A THERMOSTATICALLY-CONROLLED DHW MIXING VALVE.
Simply the Best INSTALLATION INSTRUCTIONS SOL 27 PREMIUM S & W COLLECTORS - 230016 & 230017 Technical Data & Specifications single pane safety glass. As the light strikes the absorber plate, it is converted to heat. The highly selective vacuum coating of the absorber and the thermal insulation on the back of the absorber keep heat lossed to the environment to a minimum.
Simply the Best INSTALLATION INSTRUCTIONS SOL 27 PREMIUM S & W COLLECTORS - 230016 & 230017 3 Assembly instructions 3.1 Important Information WARNING: RISK OF SCALDING. TO PREVENT THE ! SOLAR FLUID FROM BOILING IN THE COLLECTORS, THE SYSTEM SHOULD NOT BE FLUSHED OR FILLED DURING PERIODS OF STRONG SUNSHINE. System Pressure Regularly check the pressure gauge of the heat transfer circuit at the pump station. The pressure should range between 30-70 psi during all operating times.
Simply the Best INSTALLATION INSTRUCTIONS SOL 27 PREMIUM S & W COLLECTORS - 230016 & 230017 Thermal Insulation All exterior piping also requires UV and moisture protection. Insulation must be resistant to temperatures up to 356F. Use the following recommended temperature and UVresistant thermal insulation to insulate the external pipework: » Polyisocyanurate, PVC cover » Armaflex® » Mineral wool backed by aluminum mesh foil » Flexible EPDM hose 4.
Simply the Best INSTALLATION INSTRUCTIONS SOL 27 PREMIUM S & W COLLECTORS - 230016 & 230017 in or out until they are seated flush with the rivet nuts. 2. Position the grip on the collector so that it engages around the foot of the collector at the bottom. 3. Slide the grip upwards. 6. Attach the remaining grips on in the same manner. 4. Make sure it is seated in the groove of the collector trim at the top and in the bottom groove of the collector. 5.
Simply the Best INSTALLATION INSTRUCTIONS SOL 27 PREMIUM S & W COLLECTORS - 230016 & 230017 4.4 Collector Connections Inter-panel Connection WARNING: THE SPACER SHOULD NOT BE REMOVED ! UNTIL THE COLLECTORS HAVE BEEN LINKED TO ONE ANOTHER. IF THE SPACER IS REMOVED BEFOREHAND, THE CONNECTOR MAY BE DAMAGED WHEN THE SECOND COLLECTOR IS PUSHED INTO PLACE. Inter-panel connector 4. Fit the connecting clips at the junction between the collector connection and the inter-panel connector. Spacer Connecting clip 1.
Simply the Best INSTALLATION INSTRUCTIONS SOL 27 PREMIUM S & W COLLECTORS - 230016 & 230017 6. Inulate the connection using the provided thermal insulation. and plug-in connection. Inlet & Outlet Connection The inlets & outlets are plug-in style connections identical to the inter-panel connections. The installation method is the same as the inter-panel connection. Connector clip 3. Secure the connecting clip by pushing down on the locking tab. Outlet connector 4.
Simply the Best INSTALLATION INSTRUCTIONS SOL 27 PREMIUM S & W COLLECTORS - 230016 & 230017 with DIN 571, at least 10 x 80, of stainless steel, per collector. If multiple arrays of collectors are being installed on a flat roof, one behind another, the recommended spacing between them should be: At least 25 ft. (7.6 m) for vertical installations. At least 14 ft. (4.0 m) for horizontal installations. This spacing prevents excessive shading from adjacent rows for latitudes of up to 50°.
Simply the Best INSTALLATION INSTRUCTIONS SOL 27 PREMIUM S & W COLLECTORS - 230016 & 230017 Flush Mount Vertical Side-by-side This array orientation is designed for SOL 27 Premium S collectors in portrait orientation. In certain applications, SOL 27 Premium W collectors can be used as well. Flush Mount Rail Kits Part # S panels in a landscape orientation. This allows for fluid to be evacuated effectively during stagnation conditions.
Simply the Best INSTALLATION INSTRUCTIONS SOL 27 PREMIUM S & W COLLECTORS - 230016 & 230017 Horizontal Tilt Mount The horizontal tilt mount kit is designed to be adjustable in the field to three different angles. It comes partially preassembled for easy and fast field installation. The possible angles range every 5° between 10 & 45°.
Simply the Best INSTALLATION INSTRUCTIONS SOL 27 PREMIUM S & W COLLECTORS - 230016 & 230017 Typical System Layout Below is a schematic for a basic solar thermal system using Stiebel Eltron components. Specifics of this design may vary, depending on the demands of the job site.
Simply the Best INSTALLATION INSTRUCTIONS SOL 27 PREMIUM S & W COLLECTORS - 230016 & 230017 Collector Spacing For latitudes up to 50°, use the following distances for mounting solar arrays behind each other. For higher latitudes, it may not be practical at all to orient solar arrays behind each other because of the low sun angle. Array spacing for 45° Vertical Mounting on a flat roof or ground. At least 25 ft. (7.6 m) Array spacing for 45° Horizontal Mounting on a flat roof or ground. At least 14 ft. (4.
Simply the Best INSTALLATION INSTRUCTIONS SOL 27 PREMIUM S & W COLLECTORS - 230016 & 230017 to the weather must also be checked periodically for their condition. Look for signs of abrasion, wear, corrosion, contamination, or damage. Check the pH value (> 7) and frost protection level (< -20°F) of the heat transfer medium annually. 8. To periods of stagnation in excess of 60 days. 9. To excessive pressure. 10. To clouding or similar occurrence resulting from the normal intrusion of moisture into.
Simply the Best APPENDIX A SOL 27 PREMIUM S - SRCC OG-100 CERTIFICATION &(57,),(' 62/$5 &2//(&725 6833/,(5 6WLHEHO (OWURQ :HVW 6WUHHW :HVW +DWILHOG 0$ 86$ ZZZ VWLHEHO HOWURQ XVD FRP %5$1' 6WLHEHO (OWURQ 02'(/ 62/ 3UHPLXP 6 &2//(&725 7<3( *OD]HG )ODW 3ODWH &(57,),&$7,21 $ 2ULJLQDO &HUWLILFDWLRQ 0D\ ([SLUDWLRQ 'DWH 'HFHPEHU 7KH VRODU FROOHFWRU OLVWHG EHORZ KDV EHHQ HYDOXDWHG E\ WKH 6RODU 5DWLQJ &HUWLILFDWLRQ &RUSRUDWLRQറ 65&&റ DQ $16, DFFUHGLWH
Simply the Best APPENDIX A SOL 27 PREMIUM W - SRCC OG-100 CERTIFICATION &(57,),(' 62/$5 &2//(&725 6833/,(5 6WLHEHO (OWURQ :HVW 6WUHHW :HVW +DWILHOG 0$ 86$ ZZZ VWLHEHO HOWURQ XVD FRP %5$1' 6WLHEHO (OWURQ 02'(/ 62/ 3UHPLXP : &2//(&725 7<3( *OD]HG )ODW 3ODWH &(57,),&$7,21 $ 2ULJLQDO &HUWLILFDWLRQ 0D\ ([SLUDWLRQ 'DWH 'HFHPEHU 7KH VRODU FROOHFWRU OLVWHG EHORZ KDV EHHQ HYDOXDWHG E\ WKH 6RODU 5DWLQJ &HUWLILFDWLRQ &RUSRUDWLRQറ 65&&റ DQ $16, DFFUHGLWHG
Simply the Best COMMISSIONING LOG SOL 27 PREMIUM COLLECTORS The installer should fill out this sheet at the end of the installation, and leave it at the installation site. Site: System operator: Installation site: Collectors: Collectors (number / type): Collector surface area: System specifications: System height: Pipe run length: Ventilation: Solar fluid (type / concentration): Max.