Owner's Manual

Fit new spring housing - bottom
plate must face downward.
Engage outer spring loop over the
lug.
Refit the rope rotor.
Go to "Tensioning rewind spring".
If the spring has popped out and
uncoiled:
Refit it in the counterclockwise
direction - start outside and work
inward.
7HQVLRQLQJUHZLQGVSULQJ
Make a loop in the unwound starter
rope and use it to turn the rope
rotor six full revolutions in the
direction of the arrow
Hold the rotor steady -
straighten the twisted rope -
Release the rotor -
Let go of rope slowly so that it winds
onto the rotor.
The starter grip must sit firmly in the
rope guide bush. If the grip droops
to one side: Increase spring tension
by one additional turn.
When starter rope is fully extended
it must be possible to rotate the rotor
at least another half turn. If this is
not the possible, the spring is over-
tensioned and could break
Take off one turn of the rope.
Fit the fan housing on the
crankcase.
Tighten down the screws firmly.
Set the Master Control lever to
353BA029
353BA030