23 Troubleshooting Guide
Trimmer /
Brushcutter cuts out
during operation.
1 LED glows
red.
Battery too hot / too
cold.
Remove the connecting cord, @ 14.2.
Allow the trimmer / brushcutter and battery to cool down
gradually at ambient temperatures of about 50 °F to 68 °F
(10 °C to 20 °C).
3 LEDs glow
red.
Trimmer /
Brushcutter too hot.
Run-time is too short. Battery not fully
charged.
Charge the battery as described in its instruction manual.
Useful life of battery
has been reached or
exceeded.
Have the battery checked by an authorized STIHL servicing
dealer.
Always remove the connecting cord before carrying out any inspection, cleaning or maintenance.
Condition LEDs on
Battery
Cause Remedy