Instruction Manual

FSA 65, FSA 85
English
17
The LED (1) on the charger may glow
continuously green or flash red.
Green continuous light ...
... indicates the following:
The battery
is being charged
is too hot and must cool down
before charging
See also "LEDs on battery".
The green LED on the charger goes off
as soon as the battery is fully charged.
Red flashing light ...
... may indicate the following:
No electrical contact between
battery and charger – remove and
refit the battery
Malfunction in battery – see also
"LEDs on Battery".
Malfunction in charger – have
checked by a servicing dealer.
STIHL recommends an authorized
STIHL servicing dealer.
A factory-new battery is not fully
charged.
Recommendation: Fully charge the
battery before using it for the first time.
N If necessary, remove the cover from
the battery compartment before
fitting the battery, i.e. depress both
locking tabs to unlock and remove
the cover.
Fitting the Battery
N Insert the battery (1) in the power
tool – the battery slides into the
compartment – press it down
carefully until it snaps into position
the battery must be flush with the
top of the housing.
Switching on the Machine
N Make sure you have a secure and
firm footing.
N Stand upright – hold the power tool
in a relaxed position.
3)
Electromagnetic interference or
fault. Take the battery out of the
power tool and refit it. Switch on the
machine – if the LEDs continue to
flash, the battery has a malfunction
and must be replaced.
4)
Electromagnetic interference or
fault. Take the battery out of the
machine. Use a blunt tool to
remove dirt from the contacts in the
battery compartment. Refit the
battery. Switch on the power tool –
if the light emitting diodes still flash,
the power tool is faulty and must be
checked by a servicing dealer –
STIHL recommends an authorized
STIHL servicing dealer.
LED on Charger
1
3901BA019 KN
Switching On
1
3905BA011 KN