disconnect the power cable. Then remove
the feed chute and eliminate the cause of
the fault.
9.1 Motor restart inhibitor
The machine can only be started via the
switch and not by plugging the electric
cable into the mains socket.
9.2 Safety interlock
The motor/shredding tool may only be
operated when the feed chute has been
properly closed. If the right closure screw
(machine viewed from the front) becomes
loose during operation, the motor is
switched off automatically and after a few
seconds the shredding tool comes to a
standstill.
9.3 Motor run-down brake
The motor run-down brake shortens the
run-down time from when the machine is
switched off until the blades stop to a few
seconds.
9.4 Protective covers
The garden shredder is equipped with
protective covers in the feeding and
ejection areas. These include the
complete feed chute with the upper chute
and splash guard, the ejection chute
extension and the discharge flap.
The protective covers ensure that a safe
distance is maintained from the shredding
blades.
Switch on the motor only as described
in the operating instructions. (Ö 10.5)
10.1 Electrical connection of garden
shredders
Power supply and operating voltage must
correspond (see rating plate).
The power cable must be adequately
protected by fuse. (Ö 17.)
Only electric cables which are no lighter
than rubber sheathed cables
H07 RN-F DIN/VDE 0282 may be used.
The plug connections must be splash
proof. Unsuitable extension cables lead to
a loss of power and may result in damage
to the motor.
The minimum cross-section of the power
cable must be 3x1.5 mm² for a length of
up to 25 m or 3x2.5mm² for a length of
up to 50 m.
The connectors of the electric cable must
be made of rubber or have a rubber
coating and conform to the DIN/VDE 0620
standard.
This machine is intended for operation with
a power supply having a system
impedance of Z
max
at the transfer point
(house connection) of maximum
0.435 ohms (at 50 Hz).
The user must ensure that the machine is
only operated with a power supply which
meets this requirement. If necessary, this
information can be obtained from the local
electric power company.
10.2 Connecting the power cable
GHE 355:
Connect the power cable connector to
the 3-pin mains plug (1) on the
machine.
GHE 375:
Connect the power cable connector to
the 5-pin mains plug (2) on the
machine.
9. Safety devices 10. Operating the machine
Risk of injury!
Carefully read the section entitled
"For your safety" (Ö 4.) and follow
all the safety instructions before
operating the garden shredder.
Risk of injury!
Observe the instructions in section
"Warning – dangers caused by
electrical current" (Ö 4.2).
The UK version of the garden
shredder has a 10 m electric cable
with a special plug.
A plug-in fuse is included in this UK
plug.
Your electrician can provide further
information on mains connection.
When choosing a power cable, take
account of all the information in the
"Electrical connection" section
(Ö 10.1).
10