Instruction Manual
HTA 65, HTA 85
English
22
N Adjust shaft to the required length.
N Close the lever (1) and press it
down as far as stop.
N Check clamping force – if it is too
low: go to "Adjusting Clamping
Force".
The clamping force is correct when the
shaft is firmly locked in position with the
quick-release clamp closed.
Adjusting clamping force
N Swing lever (1) of quick-release
clamp up to 90° position.
N Turn screw (2) slowly clockwise as
far as stop – the lever must move
freely to closed position. If not, the
clamping force is too high.
N Close lever (1) and press it home as
far as stop – the clamping force is
too high if the lever does not locate
against the stop.
N Check clamping force.
If clamping force is too low:
N Carefully turn screw (2) clockwise a
1/4 turn at a time – this increases
the clamping force.
If clamping force is too high:
N Carefully turn screw (2)
counterclockwise a 1/4 turn at a
time – this reduces the clamping
force.
1
0022BA018 AS
90°
1
0022BA029 AS
0022BA020 AS
2
1