Instruction Manual

RE 362, RE 362 PLUS, RE 462, RE 462 PLUS
English
56
Maintenance and Care
The following maintenance intervals apply in normal operating conditions. The spec-
ified intervals must be shortened accordingly for longer daily working hours. If the
machine is only used occasionally, the intervals can be extended accordingly.
before starting work
at the end of work and/or
daily
weekly or every 40 hours of
operation
monthly
quarterly or every 200 hours
of operation
every six months or every
500 hours of operation
if faulty
if damaged
as required
Complete machine
Visual inspection (condition, leaks) X
clean XX
Oil level of the high-pressure pump check X
Oil of the high-pressure pump change X
Connectors on high-pressure hose
clean XX
grease X
Plug-type coupling of the spray lance and
the coupling sleeve of the spray gun
clean XX
Water intake strainer in the high-pressure
inlet
clean XX
replace X
High pressure nozzle
clean X
replace X
Ventilation openings clean X
Machine supports
check X
replace X