8 Checking the wet/dry vacuum cleaner
Close cover (2).
Open the filter housing cap (1) until it audibly engages.
Close the filter housing cap (1).
8.2 Checking the cooling air filter.
Press tab (1) and remove retainer (2) from top part (3).
Remove cooling air filter (4).
If the cooling air filter (4) is dirty: Clean cooling air filter.
If the cooling air filter (4) is damaged: Replace the cooling
air filter.
Insert cooling air filter (4) into retainer (2).
Insert retainer (2) into top part (3).
8.3 Checking monitoring of air velocity in the
suction hose
Switch on the wet/dry vacuum cleaner.
Close off the suction hose.
The air velocity will decrease and the LED will light up
after approx. 1 second. Also, after approx. 7 seconds a
series of short beeps will be heard.
If the LED does not light up or if a succession of short
beeps is not heard: Do not use the wet/dry vacuum
cleaner. Consult a STIHL servicing dealer.
There is a fault in the air velocity monitoring system.
8.4 Checking the float
Switch off the wet/dry vacuum cleaner and pull the mains
plug out of the socket.
Release the container locks.
Remove top part and turn it over.
Move float (1) to and fro by hand.
If the float (1) cannot be moved to and fro: Clean float (1)
with a soft brush.
If the float (1) still cannot be moved to and fro: Do not use
the wet/dry vacuum cleaner. Consult a STIHL servicing
dealer.
There is a fault in the float (1).